Condutividade Hidraulica Ex Cap.12

5
Z (cm) Unidade (cm³/cm³) Tempo (dia) 0 1 3 7 15 0 0.500 0.463 0.433 0.413 0.396 30 0.501 0.466 0.432 0.414 0.398 60 0.458 0.405 0.375 0.347 0.307 90 0.475 0.453 0.438 0.423 0.414 120 0.486 0.464 0.452 0.440 0.427 Z(cm) Armazenamento (mm) Tempo (dia) 0 1 3 7 15 0 - 30 150.2 139.4 129.8 124.1 119.1 0 - 60 291.8 266.8 248.0 234.8 220.2 0 - 90 435.2 402.1 377.6 359.3 340.9 0 - 120 580.8 540.2 511.2 488.9 466.1 Z(cm) Fluxo (mm/dia) Tempo (dia) 0.5 2 5 11 0 - 30 10.80 4.80 1.43 0.62 0 - 60 25.00 9.40 3.30 1.83 0 - 90 33.07 12.26 4.56 2.31 0 - 120 40.56 14.52 5.58 2.85 Z (cm) Potencial Matricial Tempo (dia) 0 1 3 7 15 15 -3 -23 -54 -85 -120 45 -2 -31 -59 -84 -119 75 -1 -30 -60 -88 -125 105 -3 -36 -67 -101 -124 135 -5 -37 -66 -105 -130 Z (cm) Potencial Total Tempo (dia) 0 1 3 7 15 15 -18 -38 -69 -100 -135 45 -47 -76 -104 -129 -164 75 -76 -105 -135 -163 -200 105 -108 -141 -172 -206 -229 135 -140 -172 -201 -240 -265 0.250 0.30 0 20 40 60 80 100 120 140 Profundidade (cm)

description

Planilha de Calcular Condutividade Hidraulica no Solo

Transcript of Condutividade Hidraulica Ex Cap.12

Plan1Z (cm)Unidade (cm/cm)Tempo (dia)01371500.5000.4630.4330.4130.396300.5010.4660.4320.4140.398600.4580.4050.3750.3470.307900.4750.4530.4380.4230.4141200.4860.4640.4520.4400.427Z(cm)Armazenamento (mm)Tempo (dia)0137150 - 30150.2139.4129.8124.1119.10 - 60291.8266.8248.0234.8220.20 - 90435.2402.1377.6359.3340.90 - 120580.8540.2511.2488.9466.1Z(cm)Fluxo (mm/dia)Tempo (dia)0.525110 - 3010.804.801.430.620 - 6025.009.403.301.830 - 9033.0712.264.562.310 - 12040.5614.525.582.85Z (cm)Potencial MatricialTempo (dia)01371515-3-23-54-85-12045-2-31-59-84-11975-1-30-60-88-125105-3-36-67-101-124135-5-37-66-105-130Z (cm)Potencial TotalTempo (dia)01371515-18-38-69-100-13545-47-76-104-129-16475-76-105-135-163-200105-108-141-172-206-229135-140-172-201-240-265Z (cm)Gradiente de PotencialTempo (dia)01371515 - 45-0.97-1.27-1.17-0.97-0.9745 - 75-0.97-0.97-1.03-1.13-1.2075 - 105-1.07-1.20-1.23-1.43-0.97105 - 135-1.07-1.03-0.97-1.13-1.20Z (cm)Gradiente Potencial MdioTempo (dia)0.525110 - 30-1.12-1.22-1.07-0.9730 - 60-0.97-1.00-1.08-1.1760 - 90-1.13-1.22-1.33-1.2090 - 120-1.05-1.00-1.05-1.17Z (cm)Condutividade Hidrulica Tempo (dia)0.525110 - 309.673.951.340.6430 - 6025.869.403.051.5660 - 9029.1810.083.421.9290 - 12038.6314.525.312.44Tempo 00.50.5010.458000000000000020.474999999999999980.485999999999999990306090120Tempo 10.463000000000000020.466000000000000030.405000000000000030.453000000000000010.464000000000000020306090120Tempo 30.4330.4320.3750.4380.452000000000000010306090120Tempo 70.412999999999999980.413999999999999980.346999999999999980.422999999999999990.440306090120Tempo 150.396000000000000020.398000000000000020.3070.413999999999999980.426999999999999990306090120

Umidade (cm/cm)

Profundidade (cm)

Plan2Camada 30 cmCamada 60 cmCamada 90 cmCamada 120 cmTempo mdio (dia)K () mdia (cm/cm)Tempo mdio (dia)K () mdia (cm/cm)Tempo mdio (dia)K () mdia (cm/cm)Tempo mdio (dia)K () mdia (cm/cm)0.59.670.48250.525.860.4580.529.180.4480.538.630.47023.950.448529.400.420210.080.418214.520.45251.340.423053.050.39253.420.39655.310.438110.640.4053111.560.367111.920.373112.440.426Tempo mdio (dia)K () mdia (cm/cm) - s 0.50.000.4825-0.01820.000.4485-0.05250.000.4230-0.078110.000.4053-0.095s mdia 0.5005Z = 30 cm

Z30 = 4E-07e35.361xR = 0.9861

0.482499999999999980.448500000000000010.422999999999999990.405259.67164179104476143.94520547945205191.33593750000000070.64008620689655205Z = 60 cm

Z60 = 1E-05e31.643xR = 0.9921

0.457500000000000020.419499999999999980.392000000000000020.3664999999999999925.8620689655171829.40000000000000573.04615384615385621.5642857142857107Z = 90 cm0.447750000000000040.417750000000000010.395749999999999990.3727499999999999729.18382352941165410.0787671232877083.41718749999999321.9218749999999989Z = 120 cm0.469499999999999970.451749999999999980.438249999999999970.4259999999999999938.6285714285712714.5200000000000675.31428571428571232.4428571428571444

Umidade (cm/cm)

Condutividade Hidrulica