Content
1 SystemDescription..................................................................................................................................4
1.1 Objectives........................................................................................................................................4
1.2 Generalconceptandarchitecture...................................................................................................4
1.3 DisplayAHD1019............................................................................................................................6
1.3.1 ControlPanelsforAHD1019...................................................................................................7
1.3.2 Graphicalvisualization.............................................................................................................8
1.4 DataStationsforAcquisitionandProcessing................................................................................21
1.4.1 AnalogdatastationAHDSAS15...........................................................................................21
1.4.2 BinarydatastationAHDPS47...............................................................................................22
1.4.3 CentralUnitAHD882............................................................................................................23
1.4.4 InterfaceConverterAHDUCC...............................................................................................24
1.4.5 InterfaceConverterAHDUIC................................................................................................25
1.5 OnDutySystem.............................................................................................................................26
1.6
Positionand
Navigation
Lights
Monitoring
and
Control
...............................................................
27
2 VideoSystem(Option)...........................................................................................................................28
3 HydrostaticLevelTransmitterAHDS200(Option)...............................................................................31
8/10/2019 Sistema de Monitoramento Para Iate de 35m
4/32
4
1 System Description
1.1 Objectives
Alarm and visualization systems take an important place on modern ships. The volume of informa-
tion is constantly increasing. It is therefore of great importance to collect data carefully for diagnostic
purposes.
Bning Automationstechnologie has taken up this challenge by developing a modular and decentra-
lized ship alarm and control system for professional use.
This document illustrates the structure of the system for your application. Included components are
described and their operation explained.
It is not intended to deeply discuss technical details, but to give an overview of the main characteris-
tics and the automation possibilities, based on previous projects realized by Bning.
1.2
General concept and architecture
Bning Alarm & Monitoring System is defined as a combination of systems which are interconnected
in order to allow centralized access to sensor information or command/control from workstations,with the aim of increasing safe and efficient ship's management by suitably qualified personnel.
The Bning Alarm & Monitoring System was developed for the Yacht segment and can be used for
all yachts of all sizes. The system is prepared to work with and to integrate other Bning devices as
well as other manufacturers systems, such as radar and navigation systems.
The system consists of displays on the bridge with integrated computers that are able to receive all
the information from the sensors of the ship through a connection with the CAN Bus Network.
Behind the screens, the ship alarm system data stations receive and transmit data for the sensors and
actuators, and communicate with each other via CAN Bus network, a high-speed data network, de-
signed to connect electronic units, largely applied in the automotive, aero and maritime industry.
8/10/2019 Sistema de Monitoramento Para Iate de 35m
5/325
Picture 1 CAN-Bus Concept
8/10/2019 Sistema de Monitoramento Para Iate de 35m
6/32
6
1.3 Display AHD 1019
Provided locations of visualization units:
1 pce. AHD 1019 19 visualization unit in Pilothouse
1 pce. AHD 1019 19 visualization unit in Crew Mess
1 pce. AHD 1019 19 visualization unit in Engine Control Room (ECR)
1 pce. AHD 1019 19 visualization unit in Captains Cabin
Additional displays from 6,5 to 19are optionally available
The AHD 1019operates as centralized control- and display platform, processing and visualizing all
available data in the system. The display system is designed for flush mounting into control consoles
and provides a front side degree of protection of IP67.
Picture 2 - AHD 1019 Visualization Unit
8/10/2019 Sistema de Monitoramento Para Iate de 35m
7/327
AHD 1019 is a high-quality product of Bning Automationstechnologie, providing a so-called Panel
Computer System. A display with a visible screen diameter of 19 is combined with a powerful com-
puter in one casing. A sophisticated design concept reduces the demand of cabling at minimum
demand of space.
By means of an innovative operation concept, all relevant systems are for the first time operated and
controlled from one position. For example, a control panel AHD-DC can be installed in the arm-rest
of the pilotchair. The connection of control panel to the system is performed by industrial CAN Bus.
Up to eight display units can be operated and controlled from one central panel. Alternatively to the
AHD-DC unit, a touch screen-based control panel AHD-DC880 can be used. The graphical display
offers the same functionality as the common control panel. The attractive and futuristic design of the
panels meets customers high demands.
All available data are processed graphically and visualized individually embedding ship profiles andgeneral arrangement plans. The AHD 1019 features a bright and daylight qualified display with high
resolution in SXGA quality. The high luminous intensity and the wide angle of view ensure the rea-
dability of messages and alarms in any case. The operating system of the integrated computer was
developed for industrial applications. It ensures highest degree of system stability and even excuses
shut downs of power supply. Moving parts as e.g. hard disks or fans are substituted by innovative
components. AHD 1019 is provided with a passive cooling system; it is shock-insensitive and emits
no disturbing ambient noise produced by rotating parts such as fans and hard disks.
1.3.1
Control Panels for AHD 1019
The control Panel AHD-DC can operate up to 8 AHD 1019 Displays. The control data are sent via
CAN Bus Network, so that the system cabling up to the displays is simpler and less expensive.
Picture 3 - AHD-DC Control Panel
8/10/2019 Sistema de Monitoramento Para Iate de 35m
8/32
8
1.3.2 Graphical visualization
The visualization of the measuring points are designed according to the specification of the
customer.
The following screens are included:
Main Manu Summary of all important Measuring Points for a main page.
Fuel tanks Visualization of the level of the tanks, alarms, status and control of the
transfer pumps.
Water tanks Visualization of the levels, alarms, status and control of the pumps.
Generators Visualization of generators
Power Management
System
Visualization of SYMAP data
Doors Visualization of the door sensors.
For all decks, a separated page can be provided.
Bilges Visualization of the bilges.
For all decks, a separated page can be provided.
Pumps Visualization of the bilges.
For all decks, a separated page can be provided.
Navigation Lights Status and control of the navigation and positioning lights
CCTV (optional) Control and visualization of the cameras of the Bning Video System
Alarms Visualization and acoustic alarms of the sensors
Events Stores all the relevant measured data. The list of events is organized in
days, and can be anytime consulted.
Engine Data Visualization of ships engine data; CAT Engines
8/10/2019 Sistema de Monitoramento Para Iate de 35m
9/329
Individual visualization pages
A variety of analog and digital displays are available to visualize system data. Ship illustrations / ren-
derings and deck layouts can be included.
Picture 4 - Visualization components
Design proposal of the pages will be made after order.
The following screenshots provide an introduction into possible system designs.
8/10/2019 Sistema de Monitoramento Para Iate de 35m
10/32
10
Menu Page
Fast access to all visualization pages is given.
Menu page can be directly addressed from all sub-pages
Picture 5 - Screenshot Menu Page
8/10/2019 Sistema de Monitoramento Para Iate de 35m
11/3211
Main Page
Full system overview at a glance
Showing major values of all sub-systems on one summary page
Display of overall levels, actual consumption and calculated range
Picture 6 - Screenshot Main Page
8/10/2019 Sistema de Monitoramento Para Iate de 35m
12/32
12
Fuel System
Bar graph readouts with exact level indicator
Indication of major and minor alarm level
Overspill indication
Full control of valves and transfer pumps
Indication of sensor status of Bilge alarm system
Overall Fuel Level, actual consumption and range calculation possible
Picture 7 - Screenshot Fuel Tanks
8/10/2019 Sistema de Monitoramento Para Iate de 35m
13/3213
Water System
Bar graph readouts with exact level indicator
Indication of major and minor alarm level; high or low level indication possible
Full control of valves and transfer pumps
Indication of sensor status of Bilge alarm system
Visualization and control of water maker system
Picture 8 - Screenshot Water Tanks
8/10/2019 Sistema de Monitoramento Para Iate de 35m
14/32
14
Power supply / Generators
Visualization of data from power management system (i.e. SYMAP)
Readout of actual voltage, amperes and power consumption
Indication of alarms from power generators (i.e. lube oil temp,)
Picture 9 - Screenshot Generators
8/10/2019 Sistema de Monitoramento Para Iate de 35m
15/3215
Doors and Hatches
Open door indication
Speed dependant alarms or warnings
Import of deck layouts
Picture 10 - Screenshot Doors
8/10/2019 Sistema de Monitoramento Para Iate de 35m
16/32
16
Navigation Lights
Status Indication including failure messaging
Full remote control
Group switching possibility
Import of deck layouts
Picture 11 - Screenshot Navigation Light Control
8/10/2019 Sistema de Monitoramento Para Iate de 35m
17/3217
Camera Control (optional)
Full control of dome cameras
Setting of presets and private zones
Sequences with automatic change-over programmable
Full screen mode
Picture 12 - Screenshot CCTV
8/10/2019 Sistema de Monitoramento Para Iate de 35m
18/32
18
Alarm and Event List
All active alarms listed; grouped in acknowledged and unacknowledged alarms
Indication of actual value, status, type of alarm, date and time of occurrence
Picture 13 - Screenshot Alarms
8/10/2019 Sistema de Monitoramento Para Iate de 35m
19/32
8/10/2019 Sistema de Monitoramento Para Iate de 35m
20/32
20
Engine Data
Data from the Caterpillar engines will be integrated and visualized with analogue gauges
Visualization of the measured data realized according to the customers specification on the
display software
CAN-Bus Interface with SAE J1939 protocol is used to poll data from the engines
Yard has to assure that this type of interface is ordered at Caterpillar.
Picture 15 Example of Engine Monitoring Page
The measured values were processed and visualized within the Bning Alarm & Monitoring System.
Activated binary alarm values of the CAT engine causes a major alarm of Bning Monitoring & Con-
trol System. Acknowledgement of alarm takes place only within Bning system; acknowledgment of
the CAT alarm system is not provided.
8/10/2019 Sistema de Monitoramento Para Iate de 35m
21/3221
1.4 Data Stations for Acquisition and Processing
The modules can be installed close to the sensors. The wiring is reduced to a minimum.
Data acquisition and control of actuators is carried out by means of analog data stations AHD-SAS
15 and serially connected binary stations AHD-PS 47 (AHD-PS 30 or AHD-PS 15).
1.4.1 Analog data station AHD-SAS 15
All sensor data are locally evaluated in data stations AHD-SAS 15. Standardization, filtering, thre-
shold monitoring, alerting and grouping are carried out by means of integrated data processing.
The arrangement of the components may vary depending on the requirement as a central or distri-
buted alarm system. Communication is designed via a redundant CAN bus for best data safety. All
alarms and values are forwarded from data stations to the visualization systems.
Picture 16 AHD-SAS15 data station with 15 analog or binary inputs
Another important characteristic of AHD-SAS 15 is the autonomous operation of the device, inde-
pendent of the availability or failure of other components. Even in case of a complete bus failure
(e.g. cable damage) alarms may be reported. For this purpose further contacts (horn, light signaling
column) are incorporated. Additionally, the device is equipped with a local input for acknowledg-ment which can be connected externally. By means of integrated LEDs alarms will be displayed
locally.
8/10/2019 Sistema de Monitoramento Para Iate de 35m
22/32
22
1.4.2 Binary data station AHD-PS47
The data stations AHD-PS47are electronic devices to be fitted into a housing (cabinet, desk, .).
They serve as decentralized collection of binary signals and serial output to be forwarded to the AHD-
SAS15.
An important feature is that the wiring is optimised, from 94 down to just 3 wires, including power
supply. Furthermore the device enables each input to be easily checked for short to ground/short to
earth.
The data station functions across a broad voltage range between 17 and 32 VDC. Working with a
wire diameter of at least 0,5mm the distance to the receiver can be up to 1,000m
Picture 17 - AHD-PS47 Binary Data Station
Alternative configurations with 30 and 15 binary inputs are also available.
8/10/2019 Sistema de Monitoramento Para Iate de 35m
23/3223
1.4.3 Central Unit AHD 882
The central unit AHD 882is a microprocessor controlled device for the monitoring of serial data with
freely configurable distribution to different messaging systems.
AHD 882 central unit can be applied in alarm systems, control systems, monitoring systems as well as
in on-duty systems.
It collects all information transmitted from the substations for processing and storage in an inte-
grated memory. AHD 882 is connected to all data stations incl. AHD-SAS15 via CAN-Bus Network,
therefore AHD 882 is able to receive all processed data.
Alarm messages (single or group messages) can be released via 16 channels that can be freely allo-
cated. Alarms and conditions can be displayed on several visualization units (i.e. AHD 1019). Anymeasurement point can be shown on one or more positions of different reporting systems, such as
the Chamber panel. Additionally, the device features 5 freely configurable group relays.
Other interfaces such as RS232, additional control inputs, acknowledgement inputs and relay out-
puts expands the functionality to handle and allow versatile application possibilities.
Figure 18 - Central Processing Unit AHD 882
AHD882featurescommunicationwithothersystemcomponentsoreventhedirectconnectionofa
alarmprintingdevice.
Aninternalmemoryrecordsthelast10,000messageswithdateandtime.Itreportsstatusandalarm
valuesanddifferencesbetweenswitchoffandonsignal.SerialRS232connectionallowsdatareadout.In
manycases,
this
functionality
is
able
to
replace
an
alarm
printer.
ConfigurationofthesystemismadebyusingaPCbasedconfigurationtool.
8/10/2019 Sistema de Monitoramento Para Iate de 35m
24/32
24
1.4.4 Interface Converter AHD-UCC
The Universal CAN Converter AHD-UCCis a microcontroller-controlled unit for logging and conver-
sion of measuring point data from communication protocols of external CAN bus networks into
Bning AHD-SAS CAN bus network.
Picture 19 - AHD-UIC Interface Converter
By that, selected data of connected external systems can be updated and monitored continuously
and visualized e.g. on graphic pages of connected colour displays.
The configuration of data communication with settings for the adaptable external data protocols and
the definition of required data conversions is performed by configuration software for Bning AHD-
SAS network.
8/10/2019 Sistema de Monitoramento Para Iate de 35m
25/3225
1.4.5 Interface Converter AHD-UIC
The data converters AHD-UICare designed to collect data from external systems via Modbus RTU
serial interfaces. Resulting messages are passed to a redundant CAN bus to ensure alarms are issued
to all added units.
Picture 20 - AHD-UIC Interface Converter
Two devices are paired to provide all data for redundant CAN bus.
Modbus RTU is a digital serial data connection. Max. possible data rate is 38,400 Baud, a maximum
of 100 values per AHD-UIC can be processed. The data retrieval is carried out sequentially, cycle time
is thus dependent on the data rate and the amount of queried data.
System conditions can lead to delays in alerting depending of cycle time.
Cabling and mounting of components is to be carried out by the yard.Pre-configured CAN bus cable in matching lengths, T-pieces, terminal adapters and terminators can
be supplied on request.
Cabling must be laid in line structure. The maximum cable length of CAN bus is to be observed, pos-
sibly repeater stations for data processing must be used.
With high quality cable a maximum cable length of 200m is possible. The AHD-UIC is a data conver-
ter that provides the interface with other suppliers equipment (i.e. SYMAP) via serial RS485 Inter-
face. All the values are then transferred to the CAN Bus network, so that the warning and alarms can
be also inserted in the ship alarm system.
8/10/2019 Sistema de Monitoramento Para Iate de 35m
26/32
26
1.5 On-Duty System
Alarms will be forwarded to the responsible personnel by an on duty system.
The system is part of the Bning alarm system.
It consists of the following components.
AHD 882 Central processing unit
AHD-PS 15B On duty panel
AHD 406-2 Cabin panel
Picture 21 Topology of On-Duty System
The AHD-882 is the central processing unit within a on-duty system on ships. It is connected to the
main system with a redundant CAN-bus and gets all the information within the system.
All the resulting status and alarm messages are sent depending on the configuration to a maximum
of 16 serial output channels. Thus, each value can be forwarded as an individual or in a group mes-
sage to the cabin panels.
8/10/2019 Sistema de Monitoramento Para Iate de 35m
27/3227
1.6 Position and Navigation Lights Monitoring and Control
Another component of the system is the control and monitoring device for the navigation lights
AHD-DPS02. It consists of a main module with 14 ports for 14 navigation lights, and extension
modules with 7 ports each.
Picture 22 - AHD-DPS02 Navigation Lights Monitoring and Control
The control of the lamps is carried out from the PC-based display on the bridge. The system also pro-
vides an emergency control panel AHD-DPS02-B21 for redundancy, in case of failures of the main
device or of the bus.
The DPS02 System is approved by GL and LR. Alternative options to control conventional or LEDlights are available. 230V or 24V Lights can be controlled.
Navigation Lights are to be supplied by yard.
8/10/2019 Sistema de Monitoramento Para Iate de 35m
28/32
8/10/2019 Sistema de Monitoramento Para Iate de 35m
29/32
8/10/2019 Sistema de Monitoramento Para Iate de 35m
30/32
Picture 2
The operat
zoom adju
era angles
Picture 2
5 - AHD-V
ing panel A
stment, cha
that can be
6 - AHD-V
751 do
HD-VCP ca
nging spee
saved and
P Contr
e camera
be installe
and rotati
estored lat
l Panel
30
anywhere
on of the c
r.
on board. I
meras, as
ts features
ell as prog
re camera
ramming pr
selection,
eset cam-
8/10/2019 Sistema de Monitoramento Para Iate de 35m
31/3231
3 Hydrostatic Level Transmitter AHD-S200 (Option)
The hydrostatic level transmitter AHD-S 200has been especially designed for shipbuilding and off-
shore applications. The transmitters are suitable for level measurement in open tanks, containers or
reservoirs.
.
Picture 27 - Sensor AHD-S200
The hydrostatic level transmitters as a standard comply with the requirements of Germanischer Lloyd
(GL).