CERTIFICAÇÃO DE PERFORMANCE E NÍVEL SONORO EM TORRES DE

RESFRIAMENTO

BRIEFING

• EVAPCO SEMCO

• CERTIFICAÇÃO DE PERFORMANCE

• VANTAGENS DA CERTIFICAÇÃO

• CERTIFICAÇÃO LEED X CERTIFICAÇÃO CTI

• NÍVEL SONORO

• COMO ESPECIFICAR

• NOVAS TECNOLOGIAS

PRESENÇA GLOBAL

20 FÁBRICAS EM 10 PAÍSES173 ESCRITÓRIOS EM 51 PAÍSES

CENTRO DE PESQUISA E DESENVOLVIMENTO COM 6000 m2

PRESENÇA GLOBAL

Johannesburg, South Africa

Cairo, Egypt

Milan, Italy

Riverstone, Australia

Shanghai, China

Madera, CA

Bryan, TX

Taneytown, MD

Greenup, ILSondrio, Italy

Beijing, China

Tongeren, Belgium

Lake View, IA

Lake Oswego, OR

Lenexa, KSRamseur, NC

Newton, IL

Aabybro, Denmark

Sao Paulo, Brazil

Selangor, Malaysia

MATRIZ

TANEYTOWN – MILFORD - USA

CERTIFICAÇÃO

CERTIFICAÇÃO

PROFISSIONAIS JOGAM PELAS MESMAS REGRAS

CERTIFICAÇÃO

CTI STD-201

PROGRAMA QUE CERTIFICA QUE A PERFORMANCE DE UM MODELO OU LINHA DE

TORRES DE RESFRIAMENTO PERFORMAM TERMICAMENTE DE ACORDO COM AS CURVAS DE PERFORMANCE PUBLICADAS PELO FABRICANTE

COM RECERTIFICAÇÃO ANUAL

http://www.cti.org/downloads/2015CertificationSpeech.pdf

CERTIFICAÇÃO

ATC-105

ACCEPTANCE TEST CODE

PARTE I - PROCEDIMENTO DE TESTE

PARTE 2 – AVALIAÇÃO DOS RESULTADOS

PARTE 3 – APÊNDICE EXEMPLO DE AVALIAÇÃO

http://www.cti.org/downloads/2015CertificationSpeech.pdf

CERTIFICAÇÃO

• GARANTIA DE PERFORMANCE SEM CUSTO ADICIONAL

• GARANTIA DE EFICIÊNCIA DO SISTEMA

• BAIXO CONSUMO DE ENERGIA

• OPERAÇÃO COM INVERSOR

• CONFIABILIDADE

• SEM PROBLEMAS DE GARANTIA POR PROBLEMAS DE RESFRIAMENTO

The REHVA European HVAC journal Volume 52 issue 2 march 2015

LEED X CTI

ANSI/ASHRAE/IES Standard 90.1-2010 (I-P Edition) Table 6.8.1G

PRODUTOS

AT – TORRES DE RESFRIAMENTO

ATW – RESFRIADOR CIRCUITO FECHADO

PRODUTOS

UT – TORRES DE RESFRIAMENTO

UTW – RESFRIADOR CIRCUITO FECHADO

PRODUTOS

LSTE – TORRES DE RESFRIAMENTO

LSWE – RESFRIADOR CIRCUITO FECHADO

PRODUTOS

PMTQ – TORRES DE RESFRIAMENTO

PMWQ – RESFRIADOR CIRCUITO FECHADO

PRODUTOS

ESWA e ESWB–RESFRIADOR CIRCUITO FECHADO

PRODUTOS

Eco HYBRID–RESFRIADOR CIRCUITO FECHADO

NÍVEL SONORO

A ABNT estabelece através da norma NBR 10151, limites máximo de ruído de acordo com o tipo de área, medido na janela do reclamante:

NÍVEL SONORO

CTI TEST CODE ATC-128

POSIÇÃO MICROFONE

NÍVEL SONORO

CTI TEST CODE ATC-128

POSIÇÃO MICROFONE

NÍVEL SONORO

ATENUADOR DE DESCARGA

SILENCIADOR DE BACIA

NÍVEL SONORO

ATENUADOR DE ENTRADA

ATENUADOR DE DESCARGA

NÍVEL SONORO

300 Ton Nominal Selection Sound Pressure Level in dB(A) at 1,5m

Unit Type Total Motor HP End Motor Opp. End Opposite Motor Side Top

AT-19-612 com Standard Fan 20 80 81 80 80 83

AT-19-612 com Low Sound Fan

Capacidade Reduzida (-5%)20 79 79 79 79 79

AT-19-612 com Super Low Sound

Fan20 78 79 78 78 73

AT-19-612 com Standard Fan e

Silenciador de Bacia20 76 78 76 76 83

AT-19-612 com Super Low Sound

Fan e Silenciador de Bacia20 70 73 70 70 72

AT-19-612 com Super Low Sound

Fan, Silenciador de Bacia e

atenuador de ruído

20 70 72 70 70 64

LSTE-10112 sem atenuadores 40 70 81 70 70 79

LSTE-10112 com atenuadores 50 60 64 60 63 63

LSTE-10118 LS sem atenuadores 30 66 77 66 66 75

LSTE-10118 LS com atenuadores 40 57 59 55 55 58