8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
1/48
P R
O
I
U S
PROCESS FIELD BUS
Data SheetD184S044U02
Field
Electromagnetic FlowmeterFXE4000
(COPAXE/MAGXE)
IT
The Electromagnetic Flowmeter (EMF) can be
used to accurately measure the flowrate of liquids
which have an electrical conductivity greater than
5 S/cm (20 S/cm for demineralized water).
The COPA-XE is a flow measurement system in a
Compact Design.
The MAG-XE flow measurement system consists
of a flowmeter primary and a remote mounted
P-converter
Stainless Steel Flowmeter Primary (Series 2000)
The basic flowmeter body is installed using threadedadapters which are matched to the pipeline connections:
Weld stubs Food Industry fittings per DIN 11851 TriClamps Wafer and fixed flange designs Certificates EHEDG, FML, 3A
Flowmeter Primary with Aluminum Housing
(Series 4000)
Flange and wafer designs DVGW Test Report Certifiable for Cold and Waste Water and Fluids other
than Water
Converter
Communication PROFIBUS DP, HARTProtocol,FOUNDATION Fieldbus, PROFIBUS PA, ASCII
Pulse output, configurable (active/passive)
Data secured in a plugin EEPROM Graphic display
IntelligentCompact and Effective
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
2/48
2
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Overview, Flowmeter Primary and Converter Designs: FXE4000 (COPA-XE)
Fixed Flange Wafer Design Fixed Flange Wafer Design Variable ConnectionsHousing Material Aluminum Housing Series 4000 Stainless Steel Housing Series 2000
Primary
Model Number DE43F DE43W DE23F DE23W DE23R,S,T,EAccuracy 0.5 % of rate
DN PN DN PN DN PN DN PN DN PN
Wafer Design 3100:1/04 16 3100:1/104 1040 Flanges DIN 31000 1040 3100 10 40 Flanges ANSI 1/840 CL150300 1/84 CL150300 Food Ind. fittings DIN 11851 3100:1/104 10
Weld stubs 3100:1/104 10TriClamp per DIN 32676 3100:1/104 10
Ext. thds. ISO 228/DIN 2999 325:1/101 10Liner Hard/soft rubber
PTFE, PFAPFA (DN 381/105/16)
PTFE (DN 101003/84)
PFA(vacuum tight)
PFA(vacuum tight)
PFA(vacuum tight)
Conductivity > 5 S/cm(20 S/cm for
demineralized water)
> 5 S/cm(20 S/cm for
demineralized water)
> 5 S/cm(20 S/cm for
demineralized water)
> 5 S/cm(20 S/cm for
demineralized water)
> 5 S/cm(20 S/cm for
demineralized water)
Electrodes SS 1.4571[316Ti], 1.4539, Hastelloy B2/C4, PlatinumIridium, Tantalum, TitaniumProcess Connection Material Steel, 1.4571[316Ti] 1.4571[316Ti] 1.4404[316L]
Protection Class IP 67 IP 67 IP 67 IP 67 IP 67Fluid Temperature * 25 to +130 C 25 to +130 C 25 to +130 C 25 to +130 C 25 to +130 C
Approvals
EEx Design TV 97, ATEX 1173X (see separate data sheet)Certifiable Cold and Waste Water, Liquids other than WaterPress. Equip. Dir. 97/23/EG Conformity Evaluation per Category III, Fluid Group 1
Certificates
3A, FML, EHEDG(Cleanability)
Converter
Supply Power 85253 V AC/16.826.4 V AC/16.8 31.2 V DCCurrent Output 0/210mA, 05 mA, 0/420 mA, 0/410/1220 mA
Pulse Output Active 24 V DC pulse or passive optocouplerExt. Zero Return Optocoupler inputExt. Totalizer Reset Optocoupler input
Forward/Reverse Metering Signal over optocoupler outputEmpty Pipe Detector from DN 10 : 3/8, signal over optocoupler output
Self Monitor yesLocal Display / Totalization yesHousing Converter housing made of Aluminum (standard), converter made of stainless steel (option)
Communication PROFIBUS DP, PROFIBUS PA, HARTProtocol, FOUNDATION Fieldbus, ASCIIProtocol (RS485)*) 25 C for stainless steel process connections
10 C for steel process connections
DN 3501000 : 1440
DN 125300 : 512
DN 3100 : 1/104
DN 3100 : 1/104 DN 3100 : 1/104
205 l/min
>V 28340 m3
>V
DN 3 DN 40
DN 50DN 100 : 24
1/101
DN 3 DN 401/10 1 1/2
DN 50 DN 1002 4
Weld Stubs TriClamp DIN 32676
Ext. Threads
Others upon request
Food. Ind. FittingsDIN 11851
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
3/48
3
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Overview, Flowmeter Primary and Converter Designs: FXE4000 (MAG-XE)
Fixed Flange Wafer Design Fixed Flange Wafer Design Variable ConnectionsHousing Material Aluminum Housing Series 4000 Stainless Steel Housing Series 2000
Primary
Model Number DE41F DE41W DE21F DE21W DE21R,S,T,EAccuracy 0.5 % of rate
DN PN DN PN DN PN DN PN DN PN
Wafer Design 3100:1/10416 - 3100:1/104 1040 Flanges DIN 31000 1040 3100 10 40 Flanges ANSI 1/8 40 CL150300 1/84CL150300 Food. Ind. Fitting DIN 11851 3-100:1/10-4 10
Weld stubs 3-100:1/10-4 10
TriClamp per DIN 32676 3-100:1/10-4 10
Ext. thds. ISO 228/DIN 2999 3-25:1/10-1 10
Liner Soft/hard rubber,PTFE, PFA
PFA(DN38:1/105/16)PTFE(DN10100:3/84)
PFA(vacuum tight)
PFA(vacuum tight)
PFA(vacuum tight)
Conductivity > 5 S/cm(20 S/cm for demineralized water)
> 5 S/cm(20 S/cm for
demineralized water)
> 5 S/cm(20 S/cm for demineralized water)
> 5 S/cm(20 S/cm for demineralized water)
> 5 S/cm(20 S/cm for demineralized water)
Electrodes SS 1.4571[316Ti], 1.4539, Hastelloy B2/C4, PlatinumIridium, Tantalum, TitaniumProcess ConnectionMaterial
Steel, 1.4571[316Ti] 1.4571[316Ti] 1.4404[316L]
Protection Class IP 67,IP 68 (Option)
IP 67,IP 68 (Option)
IP 67,IP 68 (Option)
IP 67,IP 68 (Option)
IP 67,IP 68 (Option)
Fluid Temperature * 25 to +130 C 25 to +130 C 25 to +130 C 25 to +130 C 25 to +130 C
Approvals
EEx Design TV 97, ATEX 1173X (see separate data sheet)Certifiable Cold and Waste Water, Liquids other than WaterPress. Equip. Dir. 97/23/EG Conformity Evaluation per Category III, Fluid Group 1
Certificates
3A, FML, EHEDG(Cleanability)
Converter
Supply Power 85253 V AC/16.826.4 V AC/16.8 31.2 V DCCurrent Output 0/210mA, 05 mA, 0/420 mA, 0/410/1220 mA Pulse Output Active 24 V DC pulse or passive optocoupler
Ext. Zero Return Optocoupler inputExt. Totalizer Reset Optocoupler inputForward/Reverse Metering Signal over optocoupler outputEmpty Pipe Detector from DN10 : 3/8, signal over optocoupler outputSelf Monitor yesLocal Display / Totalization yesHousing Field mount housing, 19Insert, Panel mount housing, Rail mount housingCommunication PROFIBUS DP, PROFIBUS PA, HARTProtocol, FOUNDATION Fieldbus,
ASCIIProtocol (RS485)*) 25 C for stainless steel process connections
10 C for steel process connections
DN 3501000 : 1440
DN 125300 : 512
DN 3100 : 1/104
DN 3DN 100 : 1/104 DN 3DN 100 : 1/104
DN 3DN 40
DN 50DN 100 : 24
1/101
DN 3 DN 401/10 1 1/2
DN 50 DN 1002 4
Weld Stubs TriClamp DIN 32676
Ext. Threads
Others upon request
Food Ind. FittingsDIN 11851
MAGXE
>V 205 l/min
>V
D ATAST EP C / C E
ENTER
28340 m3
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
4/48
4
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Accuracy, Reference Conditions and Principles of Operation
Reference Conditions per EN 29104
Fluid Temperature20 C 2K
Ambient Temperature20 C 2K
Supply PowerLine voltage per Name Plate UN 1 % andFrequency f 1 %
Installation ConditionsUpstream >10xDN straight sectionDownstream >5xDN straight sectionD = Flowmeter primary size.
Warm Up Phase30 min
Analog Output EffectsSame as pulse output plus 0.1 % of rate.
Principle of Operation
The Faraday Laws of Induction, which state that a voltage is generatedin a conductor when it moves through a magnetic field, form the basis forthe electromagnetic flowmeter measurements.
This measurement principle is applied to a conductive fluid which flowsin a pipe in which a magnetic field is generated perpendicular to the flowdirection (see Schematic).
The voltage which is induced in the fluid is measured at two electrodeslocated diametrically opposite to each other. This signal voltage UE isproportional to the magnetic induction B, the electrode spacing D andthe average fluid velocity v.
Since the magnetic induction B and the electrode spacing D are constantvalues the signal voltage UEis proportional to the average flow velocity v.
The equation for calculating the volumetric flowrate shows that the signalvoltage UEis linear and proportional to the volumetric flowrate.
The induced signal voltage is converted into scaled, analog and digitaloutput signals in the converter.
Q
Rangemax
0 0.2 0.4 0.6 0.8 1 2 4 6 8 10
6
5
4
3
2
1
0 2 4 6 8 10 20 40 60 80 100 %
Standard Calibration (Pulse Output):Q>0.07 Rangemax 0.5 % of rateQ
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
5/48
5
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Installation Requirements and Grounding
In- and Outlet Pipe SectionsThe metering principle is independent of the flow profile as long as standing eddies do not extend into the metering section, such as may occurafter double elbows, tangential inflow or partially open gate valves upstream of the flowmeter. It is recommended that flow control devices beinstalled downstream from the flowmeter primary. It is essential to assure
that the meter tube is always completely filled with fluid.
Our experience indicates that in most installations, straight inlet sections3 x D long and straight outlet sections 2 x D long are sufficient.
For test stands the reference conditions in EN 29104 are to be maintained. For certified instruments, there are special in and outlet lengthrequirements (see Page 7).
Electrode AxisThe meter can be installed in vertical, horizontal or sloped pipelines. Theelectrode axis should be horizontal, if at all possible. A vertical electrodeaxis orientation should be avoided. An ideal installation is shown in Fig. 3 .
GroundingThe grounding of the flowmeter primary is essential not only for safetyreasons, but also of importance to assure trouble free operation of theelectromagnetic flowmeter. The ground screws on the flowmeter primaryare to be brought to ground potential. For technical reasons this potentialshould be identical to the potential of the metering fluid, if possible.
For plastic or insulated lined pipelines the fluid is grounded by installingground plates. When there are stray potentials present in the pipeline, aground plate is recommended on both ends of the meter primary.
For flowmeter primaries with hard or soft rubber liners, sizes DN 125/5and larger, a conductive element is incorporated in the liner. This assures
that the fluid is grounded.To comply with the EMC and Low Voltage Regulations the connectionbox/converter must be grounded in addition to the meter tube of theflowmeter primary. The green/yellow cable, included with the shipment,should be used to make this connection. Connection examples areshown in the Section Interconnection Diagrams starting on Page 37.
Installation in Larger Size PipelinesThe flowmeter primary can readily be installed in larger pipeline sizes byutilizing reducers (e.g. flanged reducers DIN 2616). The pressure dropwhich results from the reduction can be determined from the NomographFig. 4. The pressure drop is determined in the following manner:
1. Calculate the diameter ratio d/D.2. Determine the flow velocity from the Flow Range Nomograph
Fig. 5 .3. Read the pressure drop on the YAxis in Fig. 4.
Electrode axis
Fig. 3: Electrode Axis
100
10
1
0.5 0.6 0.7 0.8 0.9
v=8m/s
7m/s
6m/s
5m/s
4m/s
3m/s
2m/s
1m/s
D d
8
V
Diameter Ratio d/D
PressureDrop
p[mbar]
Flanged reducer
d = EMF Inside diameter
D = Pipeline inside diameterv = Flow velocity [m/s]p = Pressure drop [mbar]
Pressure Drop Nomograph for EMF with FlangedReducers = 8 2
Fig. 4: Nomograph for EMF Pressure Drop Determinations
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
6/48
6
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Flowmeter Sizes, Pressure Ratings, Flow Range Nomograph
Flowrate NomographThe volumetric flowrate is a function of both the flow velocity and theflowmeter size. The Flow Range Nomograph shows the flowrates which
can be metered with a specific flowmeter size and also which flowmetersizes are suitable for a specific flowrate.
Example:Flowrate = 7 m3/h (maximum value = flow range end value). Suitable areflowmeter primary sizes DN 20 : 3/4 to DN 65 : 21/2 for flow velocitiesbetween 0.5 and 10 m/s.
Meter SizeDN Inch
Std. Press.Rating
PN
Min. Flow RangeFlow Velocity0 to 0.5 m/s
Max. Flow RangeFlow Velocity0 to 10 m/s
3 1/104 5/32
6 1/4
4040
40
0 to 0.2 l/min0 to 0.4 l/min
0 to 1 l/min
0 to 4 l/min0 to 8 l/min
0 to 20 l/min 8 5/16
10 3/815 1/220 3/4
40404040
0 to 1.5 l/min0 to 2.25 l/min0 to 5.0 l/min0 to 7.5 l/min
0 to 30 l/min0 to 45 l/min0 to 100 l/min0 to 150 l/min
25 132 11/440 11/2
404040
0 to 10 l/min0 to 20 l/min0 to 30 l/min
0 to 200 l/min0 to 400 l/min0 to 600 l/min
50 265 21/280 3
404040
0 to 3 m3/h0 to 6 m3/h0 to 9 m3/h
0 to 60 m3/h0 to 120 m3/h0 to 180 m3/h
100 4125 5150 6
161616
0 to 12 m3/h0 to 21 m3/h0 to 30 m3/h
0 to 240 m3/h0 to 420 m3/h0 to 600 m3/h
200 8250 10300 12
10/1610/1610/16
0 to 54 m3/h0 to 90 m3/h0 to 120 m3/h
0 to 1080 m3/h0 to 1800 m3/h0 to 2400 m3/h
350 14400 16450 18500 20
10/1610/1610/16
10
0 to 165 m3/h0 to 225 m3/h0 to 300 m3/h0 to 330 m3/h
0 to 3300 m3/h0 to 4500 m3/h0 to 6000 m3/h0 to 6600 m3/h
600 24700 28800 32
101010
0 to 480 m3/h0 to 660 m3/h0 to 900 m3/h
0 to 9600 m3/h0 to 13200 m3/h0 to 18000 m3/h
900 361000 40
1010
0 to 1200 m3/h0 to 1350 m3/h
0 to 24000 m3/h0 to 27000 m3/h
2
l/min l/sm /h3
2
3
456
810
2
3
456
8
5
2
34
56
810
8
654
3
2
10
54
3
2
4
3
108
654
3
2
4
2
3
456
8
8
654
3
2
8
654
3
2
4
3
210
10
10
2
3
456
8
2
3
456
810
2
3
456
810
1
2
3
456
810
10
8654
3
2
108
654
3
2
3
2
1108
654
3
2
2
3
456
8
2
3
456
810
1
1
8
6
54
3
2
102
10
8654
3
2
1
3
456
8
210
0.50.60.81 2 3 5 6 8 10
m/s
DN
200
DN
250DN300D
N350D
N400
DN
450D
N500D
N600D
N700D
N800
DN
900D
N1000
DN
100
DN
80
DN
65
DN
50
DN
10
DN
15D
N20D
N25
DN3
2DN
40
DN
125D
N150
DN
3
DN
4
DN
6
Flowrate
Example
Fig. 5: Flow Range Nomograph DN 3 to DN 1000 : 1/10 to 40
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
7/48
7
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Agency Approved EMF
ApprovalsThe design of the measurement instrument Electromagnetic VolumeFlowrate Totalizer with Electrical Counter has been approved by the National Institute for Science and Technology (PhysikalischTechnischenBundesanstalt) in Braunschweig, Germany. The following approvals havebeen granted for the Volume Flowrate Totalizer which consists of a flow
meter primary and a converter:
Appendix (EO6) or Appendix 5 (EO5) of the Certification Regulationsof 1988 apply to the Electromagnetic Volume Flowrate Totalizerwith Electrical Counter.
CertificationThe Electromagnetic Volume Flowrate Totalizer is certified on the test
stands in Gttingen, Germany which have been approved for certificationcalibrations. After the calibration has been completed, the parameterswhich impact the Certification Regulations, can only be changed in thepresence of a Certification Agent.
Approved Flowmeter Sizes for Cold Water and Waste
Water
Approved Flowmeter Sizes for Liquids other than Water
Min. flow range:approx. 2.5 m/s.Max. flow range:approx.10 m/s.
The actual flow ranges must be in accord with the values listed in theTables. Subsequent range changes require a new calibration on anagency certified test stand.
Installation Requirements for Volume Flowrate TotalizersThe following installation requirements are to be observed:For Cold Water and Waste Water the lengths of the straight pipelinesections must be at least 5 times the flowmeter size upstream and atleast 2 times downstream. For Liquids other than Water (milk, beer,
wort, brine) the values listed in the brackets in Fig. 6 apply.
For flow metering in both directions (forward and reverse) straight sections are required on both sides of the flowmeter primary with a length ofat least 5 times the flowmeter size for Cold Water and Waste Water approved flowmeters and at least 10 times for Liquids other than Waterapproved flowmeters. The piping system must always be completely full.
The signal cable length may not exceed 50 m.
6.221 Electromagnetic Volume Flowrate Totalizerwith a Class B Electrical Counter forCold Water and Waste Water
87.12
5.721 Electromagnetic Volume Flowrate Totalizerwith Electrical Counter for Liquids other than Water87.05
Meter SizeDN Inch
Min. Allow. Flow RangeEnd Value (approx. 2 m/s)
Max. Allow. Flow RangeEnd Value (approx. 10 m/s)
25 132 11/440 11/2
0 to 2.4 m3/h0 to 5 m3/h0 to 9 m3/h
0 to 12 m3/h0 to 25 m3/h0 to 45 m3/h
50 265 21/280 3
0 to 14 m3/h0 to 24 m3/h0 to 36 m3/h
0 to 70 m3/h0 to 120 m3/h0 to 180 m3/h
100 4125 5150 6
0 to 56 m3/h0 to 84 m3/h0 to 128 m3/h
0 to 280 m3/h0 to 420 m3/h0 to 640 m3/h
200 8250 10300 12
0 to 220 m3/h0 to 360 m3/h0 to 500 m3/h
0 to 1100 m3/h0 to 1800 m3/h0 to 2500 m3/h
350 14400 16500 20
0 to 700 m3/h0 to 900 m3/h0 to 1420 m3/h
0 to 3500 m3/h0 to 4500 m3/h0 to 7100 m3/h
600 24700 28800 32
0 to 2000 m3/h0 to 2800 m3/h0 to 3600 m3/h
0 to 10000 m3/h0 to 14000 m3/h0 to 18000 m3/h
900 361000 40
0 to 4600 m3/h0 to 5600 m3/h
0 to 23000 m3/h0 to 28000 m3/h
Flowmeter Size and Maximum Allowable Flowrates
DN Inch QmaxLiter/min
25 132 11/4
40 11/250 2
select between60 and 200 in steps of 10select between100 and 400 in steps of 10
select between150 and 750 in steps of 50select between250 and 1000 in steps of 50
65 21/280 3
100 4150 6
select between400 and 2000 in steps of 100select between700 and 3000 in steps of 100select between900 and 4500 in steps of 100select between2000 and 10000 in steps of 500
Minimum Flowrates and Fluids
DNInch
Minimum Flowrate l/min Fluid
25 132 11/440 11/250 2
8 5 20 200
Beer, Milk, SyrupBeer, Milk, SyrupBeer, MilkBeer, Wort
65 21/280 3100 4150 6
500 50020002000
Milk, Wort, BeerMilk, Wort, BeerBrine, WortBrine
D d
8
5 x DN (10 x DN) 2 x DN (5 x DN)
5 x DN (10 x DN) For forward andreverse flow metering
Fig. 6: Pipeline Installation, Reductions as Required
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
8/48
8
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Specifications: Flanged Design Models DE41F/DE43F,Wafer Design Models DE41W/DE43W
AttentionLlimits for the allowable fluid temperature (TS) and allowablepressure (PS) are a function of the liner and flange materialsof the flowmeter (see instrument Name Plate).
Material Load Curves for Model DE41F/DE43F(Flanged Design)
Max. Temperature90 C for hard/soft rubber linersMax. Temperature130 C for PTFE/PFA liners
Max. Temperature90 C for hard/soft rubber linersMax. Temperature130 C for PTFE/PFA liners
Max. Temperature90 C for hard/soft rubber linersMax. Temperature130 C for PTFE/PFA liners
Max. Temperature90 C for hard/soft rubber linersMax. Temperature130 C for PTFE/PFA liners
JIS 10K-B2210 Flanges SS 1.4571[316Ti] or Steel
Liner: PTFE, hard/soft rubber (limited to 90 C)
Max. Temperature 90 C for hard/soft rubber liners
Max. Temperature 90 C for hard/soft rubber liners
!
Temperatur / Temperature (TS) [C]
Druck/Pressure(PS)[bar] PN 40
PN 25
PN 16
PN 10
0
5
10
15
20
25
30
35
40
45
30 20 10 0 10 20 30 40 50 60 70 80 90 100 110 120 130
Fig. 7: DINFlanges SS 1.4571[316TI] to DN 600
Temperatur / Temperature (TS) [C]
Druck/Pressure(PS)[bar]
300 lb/CL 300
15 0lb /CL 150
0
510
15
20
25
30
35
40
45
50
55
30 10 10 30 50 70 90 110 130
Fig. 8: ANSIFlanges SS1.4571[316TI]to 12 (CL150/300), to 40 (CL150)
PN 40
PN 25
PN 16
PN 10
Temperatur / Temperature (TS) [C]
Druck/
Pressure(PS)[bar]
0
5
10
15
20
25
30
35
40
45
30 10 10 30 50 70 90 110 130
Fig. 9: DINFlanges Steel to DN 600
Meter SizeDN Inch
Material PN TS [C] PS [bar]
32100 11/4 4 SS 1.4571[316Ti] 10 25 to +130 10
32100 11/4 4 Steel 10 10 to +130 10
300 lb/CL 300
150 lb/CL 150
Temperatur / Temperature (TS) [C]
Druck/Pressure(PS)[b
ar]
0
5
10
15
20
25
30
35
40
45
50
55
30 10 10 30 50 70 90 110 130
Fig. 10: ANSIFlanges Steel to 12 (CL150/300), to 40 (CL150)
6
7
8
9
10
11
12
13
14
15
16
17
DN 700 PN 16
DN 900 PN 16DN 800 PN 16
DN 1000 PN 16
DN 900 PN10DN 800 PN 10DN 700 PN 10
DN 1000 PN 10
Temperatur / Temperature (TS) [C]
Druck
/Pressure(PS)[bar]
-30 -20 -10 0 10 20 30 40 50 60 70 80 90
Fig. 11: DINFlanges SS 1.4571[316Ti} DN 700DN 1000
DN 700 PN 16
DN 900 PN 16DN 800 PN 16
DN 1000 PN 16
DN 900 PN 10DN 800 PN 10DN 700 PN 10
DN 1000 PN 10
Temperatur / Temperature (TS) [C]
Druck/Pressure
(PS)[bar]
6
7
8
9
10
11
12
13
14
15
16
17
-10 0 10 20 30 40 50 60 70 80 90
Fig. 12: DINFlanges Steel DN 700DN 1000
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
9/48
9
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Material Load Curves for Models DE41W/DE43W(Wafer Design)
(PFALiner, Wafer Design) l
General Specifications
Min. allow. Pressure as a function of Fluid Temperature
Other meter sizes, press. ratings and Temp. Classes upon request
Max. Allowable Cleaning Temperature
If the ambient temperature > 25, then the difference must be subtractedfrom the max. cleaning temperature.
Tmax C where C = TAmb 25 C)
Max. allow. Fluid Temperatures as a Function of the
Ambient Temperatures for Flowmeters with Steel Flanges
Max. allow. Fluid Temperature as a Function of the
Ambient Temperature for Flowmeters with SS Flanges
Materials, Flowmeter Primary
Process Connection Materials
Protection Class per EN 60529IP 67IP 68 (only for MAGXE flowmeter primary)
Pipeline VibrationsMaximum allowable 15 m/s2(10 150 Hz)
DesignsThe flanged flowmeters comply with the installation lengths defined inVDI/VDE 2641, ISO 13359 or DVGW (Working Paper W420, DesignWP, ISO 4064 short).
DN Inch TSmax[C] TSmin[C] PSmax[bar]
3100 1/10 4 130 10 16 (CL150)
Liner Meter SizeDN Inch
POperatembar abs.
at TOperateC
Hard rubberKTW approved
15 250 1/2 10 0 < 90300 1000 12 40 0 < 90
Soft rubberKTW approved
50 250 2 10 0 < 90300 1000 12 40 0 < 90
PTFE 10 800 3/8 32 270500
< 20< 130
PFA 3 100 1/10 4 0 < 130
CIPCleaning LinerPrimary TmaxC t
maxMinutes T
Amb.CSteam cleaning PTFE, PFA 150 60 25Liquid cleaning PTFE, PFA 140 60 25
60
13050
25
Fluid Temperature C
Ambient Temperature C
20
10 0
Temperature range for COPAXETemperature range for MAGXE
Max. allowable fluid temperature for Hard/soft rubber liner 90 CMax. PTFE/PFA 130 Callowable fluid temperature for
Comment:
Fig. 13 Max. allow. Fluid Temperatures as a Function of the AmbientTemperatures for Flowmeters with Steel Flanges
Ambient Temperature C
Fluid Temperature C130500
60
25
20
25
Temperature range for COPAXETemperatur MAGXEe range for
Comment:
Max. allowable fluid temperature for Hard/soft rubber liner 90 CMax. PTFE/PFA 130 Callowable fluid temperature for
Fig. 14: Max. allow. Fluid Temperature as a Function of the AmbientTemperature for Flowmeters with Stn. Stl. Flanges
Part Standard Options
Liner PTFE, PFA, hardrubber, soft rubber
Signal and groundelectrodes for hard rubber,
soft rubber
SS 1.4571 [316Ti]
Hast. B2 (2.4617),Hast. 2 C4, Titanium,
Tantalum,
PlatinumIridium PTFE
PFAHast. C4 (2.4610) SS 1.4571 [316Ti]
Hast. B2 (2.4617)Titanium, TantalumPlatinumIridium
Ground plate for flangedand waferdesign flowmeters
SS 1.4571 [316Ti] Upon request
Protection plate SS 1.4571 [316Ti] Upon request
Part Standard Options
FlangesDN 3 15 : 1/101/2DN 20 300 : 3/412
SS 1.4571 [316Ti] (standard)Steel (galvanized) 1.4571[316Ti]
DN 350 1000 : 1440 Steel (painted) 1.4571[316Ti]
Part Standard Options
HousingDN 3 DN 3001/10 12
Two piece housingCast Alum., painted,Paint coat, 60 m thick RAL 9002
DN 350 100014 40
Welded steel construction,paintedPaint coat, 60 m thick RAL 9002
Connection box Cast Alum., painted,Paint coat 60 m thickFrame: dark gray, RAL 7012Cover: light gray, RAL 9002
Meter tube SS 1.4301 [304]
PgConnector Polyamide PVDF
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
10/48
10
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Specifications: Stn. Stl. Flowmeter, Mod. DE21_ or DE23_, DN 3 to DN 100 : 1/10 to 4
Material Loads for Model DE21_ or DE23_,(with variable process connections)
Material Loads Curves for Flanged FlowmetersModel DE21F/DE23F
Liner: PFA
Liner: PFA
JIS 10K-B2210 Flanges SS 1.4571 [316Ti] or Steel
Material Loads Curves for Wafer DesignFlowmeters Model DE21_/DE23_
Liner: PFA
JIS 10K-B2210 Wafer Design
Minimum Allowable Absolute Pressure
Maximum Allowable Cleaning Temperature
If the ambient temperature > 25, then the difference must be subtractedfrom the max. cleaning temperature.
Tmax C, where C = (TAmb25 C).
Maximum Allowable Temperature Shock
*) Higher temperatures are allowed for CIP/SIP cleaning for limited time periods, see Table Maximum Allowable Cleaning Temperature.
Process ConnectionsLiner PFA
Meter SizeDN Inch
PSmax.[bar]
TSmax.[C]
TSmin.[C]
Wafer Design 3 50 1/10265100 24
40(CL300)16(CL150)
130*130*
25 25
Weld stubs per ISO 2037 25100 14 10 130* 25
Weld stubs per DIN 2463 10100 3/84 10 130* 25
Weld stubs per DIN 11850 10100 3/84 10 130* 25
Food Ind. ftgs per DIN 11851 3100 1/104 10 130 25
TriClamp per DIN 32676 3100 1/104 10 121 25
External threads ISO 228 3 25 1/101 10 130* 25
Meter Size Material PN TS [C] PS [bar]
DN 251001 4
SS 1.4571[316Ti] 10 25 to +130* 10
Steel 10 10 to +130* 10
Temperatur / Temperature (TS) [C]
Druck/Pressure
(PS)[bar] PN 40
PN 25
PN 16
PN 10
0
5
10
15
20
25
30
35
40
45
30 20 10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 *)
Fig. 15: DINFlanges SS 1.4571 [316Ti] to DN 100
Temperatur / Temperature (TS) [C]
Druck/Pressure(P
S)[bar]
300lb/CL300
150lb/CL150
0
5
10
15
20
25
30
3540
45
50
55
30 10 10 30 50 70 90 110 130 *)
Fig. 16: ASMEFlanges SS 1.4571 [316Ti] to 4
Meter Size Material PN TS [C] PS [bar]
DN 3210011/4 4
SS 1.4404[316L]SS 1.4435[316L]SS 1.4301[304]
10 25 to +130 10
Liner Meter Size POperatembar abs
at TOperateC
PFA DN 3 1001/10 4
0 130*
CIP-Cleaning Liner TmaxC
TmaxMinutes
TAmbC
Steam cleaningLiquid cleaning
PFAPFA
150140
6060
2525
Liner Temp. Shockmax. Temp. Diff. C
Temp. GradientC/min
PFA any any
Temperatur / Temperature (TS) [C]
Druck/Pressure(PS)[bar]
PN 40/CL300
PN 25
PN 16/CL150
PN 10
0
5
10
15
20
25
30
35
40
45
60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 100 110 120 130* 140
Fig. 17:
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
11/48
11
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Temperature Diagram
Fluid Temperatures25 C to +130 C, CIPcleanable, see Temperature Diagram andMax. Allowable Cleaning Temperature.
Storage Temperature
20 C to +70 C
Materials, Flowmeter Primary
Process Connection Materials
Gasket Material
Protection Class per EN 60529IP 67 StandardIP 68 (only for MAGXE flowmeter primary)
Pipeline VibrationsMaximum allowable 15 m/s2(10 150 Hz)
Liner Mate-rial
Electrode Material Electrodes Design
Standard Options Standard Options
PFA Hast.C4(1.4539 forFood Ind.fittings &
TriClamp
Hast.B2SS 1.4539SS1.4571[316Ti]
Tantalum,Titanium,PlatinumIridium
Flat head Pointedhead( DN 10
3/8
Standard
Flanges per DIN SS 1.4571 [316Ti]Wafer Design None
Weld stubs SS 1.4404 [316L]
Food Ind. Fittings per DIN 11851 SS 1.4404 [316L]
TriClamp per DIN 32676 SS 1.4404 [316L]
External threads SS 1.4404 [316L]
Connection Box Standard Option
COPAXE Cast Alum., painted,Paint colorsFrame: dark gray, RAL 7012Cover: light gray, RAL 9002
Converter housing made completely of Stn. Stl.1.4301 [304]
MAGXE SS 1.4301 [304]
Meter Tube SS 1.4301 [304]
PGConnector Polyamide PVDF
Housing,Flowmeter Primary
Deep drawn housing SS 1.4301 [304]
60
50130
Fluid Temperature C
Ambient Temperature C
25
20
25 0
Temperature range for MAGXE
Temperature range for COPAXE
Fig. 18: Maximum Allowable Ambient Temperatures as a Functionof the Fluid Temperature for Stn. Stl Process Connectionsand Wafer Designs
Process Connections Gasket Material
Wafer Design None
Weld stubs, Food Ind. Fittings,TriClamp, External Threads
EPDM (EthylenePropylene) std.with FDAApproval, Silicone withFDAApproval (Option)
Housing flat gasket Silicone
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
12/48
12
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Dimensions Flowmeter Primary Flanges per DIN and ANSI, Mod. DE41F & DE43F
72
35
L*
D
C
F
E
95
199120
12080
35
67
MAG-XE COPA-XE MAG-XE COPA-XE
DN 3 100 : 1/10 4Tolerance: L*+03
DIN Flanges
Dimensions Weight appr. kgDN PN 1) D L2)3) F C E Compact Design Remote Primary38101520
1040104010401040
909095
105
130200200200
281281281292
62626273
157157157168
55.55.56
44.54.55
25324050
1040104010401040
115140150165
200200200200
292297301337
73788290
168173177185
6.58
8.511
5.57
7.59
6580
100
104010401016
185200220
200200250
365377417
104110130
199205225
161920
131617
1) Other pressure ratings upon request2) If one ground plate (mounted on one flange) is installed, the dimension L increases as follows: DN 3 100:1.104 by 3 mm.3) If one protection plate (mounted on one flange) is installed, the dimension L increases as follows: DN 3 100:1.104 by 6 mm.4) If two protection flanges (mounted to each ANSI flange, old lay length) are installed the dimension L increases as follows:
1/10 3 by 20 mm, 4 and larger by 25 mm5) Connection flange DN 106) Connection flange 1/2
ANSI Flanges
For dimensions F, C, E see Table DIN Flanges
Dimensions WeightCompact Design Remote Primary
CL 150 CL 300 L 3)4) CL 150 CL 300 CL 150 CL 300DN Inch D D ISO 13359 ABB (old lay length) appr. kg appr. kg appr. kg appr. kg
385)
101520
1/85/166)
3/86)
1/23/4
89898998
969696
118
130200200200
130270270270
5.55.55.56
5.55.55.56
44.54.55
44.54.55
25324050
11 1/41 1/2
2
108118127153
124134156165
200200200200
270280280280
6.58
8.510
6.58
8.510
5.57
7.59
5.57
7.59
6580
100
2 1/23
4
178191
229
191210
254
200200
250
330340
400
1417
18
1417
18
1316
17
1316
17
ISO Projection Method EAll dims in mm
Fig. 19: Dimensions Flowmeter Primary DN 3 :1/10 to DN 100:4, Flanges per DIN and ANSI
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
13/48
13
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Dimensions Flowmeter Primary Flanges per DIN and ANSI, Mod. DE41F & DE43F
Tolerance: L* DN 125 200 : 5 8 +03 ; DN 250 500 :1020+05
DIN Flanges
Dimensions Weight appr. kg
DN PN 1) D L F G G1 H Compact Design Remote Primary
125 1016 250 250 148 292 199 250 31.0 27.0
150 1016 285 300 179 313 220 285 33.0 29.0
200200
1016
340340
350350
179207
344344
251251
340340
55.055.0
53.053.0
250250
1016
395405
450450
250250
372372
279279
405405
81.081.0
79.079.0
300
300
10
16
445
460
500
500
250
250
415
415
322
322
505
505
86.0
86.0
81.0
81.0
72
35
D
L*
> V 2 05 l /mi n28340 m3>V
199
120
12
0
D
F
G
80
35
67
G
1
103
H
MAG-XE COPA-XE MAG-XE COPA-XE
DN 125 300 : 5 12
1) Other pressure ratings upon request2) If two protection flanges (mounted to each ANSI flange, old lay length) are installed the dimension L increases
as follows: 5 and larger by 25 mm
ANSI Flanges
For dimensions F with ANSI Flanges see Table DIN Flanges.
Dimensions Weight
Compact Design RemotePrimary
CL 150 CL 300 L 2) CL 150 CL 300 CL 150 CL 300
DN Inch D D ISO 13359 ABB (old lay length) G G1 appr. kg appr. kg appr. kg appr. kg
125 5 254 280 250 450 292 199 37.0 39.0 36.0 38.0
150 6 280 318 300 450 313 220 39.0 41.0 38.0 40.0
200 8 343 381 350 500 344 251 67.0 75.0 66.0 74.0
250 10 407 445 450 550 372 279 99.0 119.0 98.0 118
300 12 483 521 500 620 415 322 125.0 181.0 124.0 180.0
ISO Projection Method EAll dims in mm
Fig. 20: Dimensions Flowmeter Primary DN 125:5 to DN 300:12, Flanges per DIN and ANSI
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
14/48
14
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Dimensions Flowmeter Primary Flanges per DIN and ANSI, Mod. DE41F & DE43F
G
F
L*
G1
80
35
D
67
MAG-XE COPA-XE MAG-XE COPA-XE
DN 350 1000 : 14 40
Tolerance: L* DN 350 500 :1420 +05 ; DN 600 1000 :2440+010
1)Other pressure ratings upon request
DIN Flanges
Dimensions Weight
Compact Design RemotePrimary
DN PN 1) D L F G G1 appr. kg appr. kg
350350
1016
505520
550550
250250
430430
341341
131.0145.0
126.0140.0
400400
1016
565580
600600
275275
456456
367367
160.0180.0
155.0175.0
500 10 670 650 310 492 403 196.0 191.0600 10 780 780 361 543 454 276.0 243.0
700 10 895 910 448 570 495 319.0 315.0
800 10 1015 1040 508 620 545 409.0 405.0
900 10 1115 1170 558 670 595 487.0 483.0
1000 10 1230 1300 615 720 645 579.0 575.0
ANSI Flanges
For dimensions F with ANSI flanges see Table DIN Flanges.
Dimensions Weight
Compact Design Remote Primary
CL 150 CL 300 L CL 150 CL 300 CL 150 CL 300
DN Inch D D ISO 13359 ABB (old lay length) G G1 appr. kg appr. kg appr. kg appr. kg
350 14 533 550 650 430 341 183 178 400 16 597 600 700 456 367 230 225
450 18 635 686 500 403 235 230
500 20 699 762 780 492 403 268 263
600 24 813 914 850 545 448 295 293
ISO Projection Method EAll dims in mm
Fig. 21: Dimensions Flowmeter Primary DN 350:14 to DN 1000:40, Flanges per DIN and ANSI
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
15/48
15
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Dimensions Flowmeter Primary Wafer Design, Mod. DE41W & DE43W
MAG-XE COPA-XE MAG-XE COPA-XE
DN 3 100 : 1/10 4
Process Connections DN Inch PN L B C E F WeightCompactDesign
appr. kg
WeightRemote Primary
appr. kg
Wafer Design 3 10 1/103/8 16 69 75 62 157 281 3.0 2.0
15 1/2 16 69 75 62 157 281 3.0 2.0
25 1 16 91 95 73 168 292 4.5 3.5
32 1 1/4 16 99 103 78 173 297 5.0 4.0
40 1 1/2 16 104 112 82 177 301 6.0 5.0
50 2 16 119 130 90 185 337 6.5 5.5
65 2 1/2 16 103 146 104 199 365 8.0 7.0
80 3 16 103 163 110 205 377 9.0 8.0
100 4 16 133 190 130 225 417 10.0 9.0
ISO Projection Method EAll dims in mm
Fig. 22: Dimensions Flowmeter Primary DN 3:1/10 to DN 100:4, Wafer Design
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
16/48
16
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Dimensions Stainless Steel Flowmeter Primary Flanges per DIN and ANSI, Mod. DE21F & DE23F
72
AL*
35
G
C
F
103
G1
74
205 l/min>V
>V 28340 m3
83
D
199
120
120
MAG-XE COPA-XE MAG-XE COPA-XE
DN 3 40 : 1/10 1Tolerance: L*+03
Flanges per DIN 2501
Dimensions Weight
Compact Design Remote Primary
DN PN D L F G G1 d4 A appr. kg appr. kg
38 1040 90 130 63 219 133 34.9 37 3.0 2.0
10 1040 90 200 63 219 133 34.9 37 3.0 2.0
15 1040 95 200 63 219 133 34.9 37 3.0 2.0
20 1040 105 200 66 223 137 42.9 42 4.5 3.5
25 1040 115 200 73 230 144 50.8 54 5.0 4.0
32 1040 140 200 78 235 149 63.5 62 6.0 5.0
40 1040 150 200 82 239 153 73 67 6.5 5.5
ANSI Flanges
For dimension F, d4 and A see Table DIN Flanges.1) Connection flange DN 102) Connection flange 1/2
Dimensions Weight
Compact Design Remote Primary
CL 150 CL 300 CL 150 CL 300 CL 150 CL 300
DN Inch D D L G G1 appr. kg appr. kg appr. kg appr. kg
381) 1/85/162) 89 95 130 219 133 3.0 3.0 2.0 2.0
10 3/82) 89 95 200 219 133 3.0 3.0 2.0 2.0
15 1/2 89 95 200 219 133 3.0 3.0 2.0 2.0
20 3/4 98 118 200 223 137 4.5 4.5 3.5 3.5
25 1 108 124 200 230 144 5.0 5.0 4.0 4.0
32 1 118 134 200 235 159 6.0 6.0 5.0 5.040 1 127 156 200 239 153 6.5 6.5 5.5 5.5
If one ground plate is required, L + 3 mm, material upon request.The above dimensions for COPAXE are for the design with aninvestment cast Alum. converter housing.Dimensions for stn. stl. converter housing see Page 23
ISO Projection Method EAll dims in mm
Fig. 23: Dimensions Stn. Stl. Flowmeter Primary DN 3:1/10 to DN 40:1, Flanges per DIN and ANSI
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
17/48
17
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Dimensions Stainless Steel Flowmeter Primary Flanges per DIN and ANSI, Mod. DE21F & DE23F
72
35
G
G
A
L*
Dd4
103
74
>V>V
205 l/min28340 m3
199120
120
D
83
MAG-XE COPA-XE MAG-XE COPA-XE
DN 50 100 : 2 4
Tolerance: L*+03
If one ground plate is required, L + 3 mm, material upon request.The above dimensions for COPAXE are for the design with aninvestment cast Alum. converter housing.Dimensions for stn. stl. converter housing see Page 23
Flanges per DIN 2501
Dimensions Weight
Compact Design Remote Primary
DN PN D L F G G1 d4 A appr. kg appr. kg
50 1040 165 200 207 161 104 100 10.0 8.0
65 1040 185 200 215 175 124 107 13.0 10.0
80 1040 200 200 224 181 139 107 15.0 12.0
100 1016 220 250 237 201 161 159 21.0 18.0
ANSI Flanges
For dimension F, d4 and A see Table DIN Flanges.
Dimensions Weight
Compact Design Remote Primary
CL 150 CL 300 CL 150 CL 300 CL 150 CL 300
DN Inch D D L G G1 appr. kg appr. kg appr. kg appr. kg
50 2 152 165 200 207 161 10.0 10.0 8.0 8.0
65 2 178 191 200 215 175 13.0 13.0 10.0 10.0
80 3 191 210 200 224 181 15.0 15.0 12.0 12.0
100 4 229 254 250 237 201 21.0 21.0 18.0 18.0
ISO Projection Method EAll dims in mm
Fig. 24: Dimensions Stn. Stl. Flowmeter Primary DN 50:2 to DN 100:4, Flanges per DIN and ANSI
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
18/48
18
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Dimensions Stainless Steel Flowmeter Primary Wafer Design, Mod. DE21W & DE23W
73
E
G1
F
AA*L
Di
C D
G
103
74
199
120
120
Di
13
.6
83
MAG-XE COPA-XE MAG-XE COPA-XE
DN Inch PN L1) A* A C Di D E F G G1 COPAXE(G)Wgt.~kg
MAGXE(G1)Wgt.~kg
3 4 6 81015
1/105/321/4
5/163/81/2
1040CL 150/CL 300
68 64 37 42 3 4 6 81013
45 157 62 281 198 3.5 1.5
20 3/4 78 74 42 50 18 54 161 66 289 206 4.0 1.5
25 1 90 86 54 59 24 63 168 73 303 220 4.5 2.0
32 1 1/4 98 94 62 69 30 73 173 78 313 230 4.5 2.5
40 1 1/2 103 99 67 77 36 82 177 82 321 238 5.0 3.0
1) If one ground plate is required, L + 3 mmThe above dimensions for COPAXE are for the design with an investment cast Alum. converter housing.Dimensions for stn. stl. converter housing see Page 23
DN 3 40 : 1/10 1
DN 3 8 : 1/10 5/16
ISO Projection Method EAll dims in mm
Fig. 25: Dimensions Stn. Stl. Flowmeter Primary DN 3:1/10 to DN 40:1, Wafer Design
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
19/48
19
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Dimensions Stainless Steel Flowmeter Primary Wafer Design, Mod. DE21W & DE23W
F
A*
G E
L
Di
C D
G1
103
74
120
199
120
83
MAG-XE COPA-XE MAG-XE COPA-XE
1) Installation length with 2 ground plates L + 3 mmThe above dimensions for COPAXE are for the design with an investment cast Alum. converter housing.Dimensions for stn. stl. converter housing see Page 23
DN Inch PN L1) A* A C Di D E F G G1 COPAXE(G)Wgt.~kg
MAGXE(G1)Wgt.~kg
50 2 1040
CL150/300
117 112 95 47 100 185 50 297 214 6.5 4.0
65 2 1/216
CL 150
103 99 111 62 116 199 58 319 236 7.0 4.5
80 3 103 99 128 74 133 205 66.5 334 251 8.5 6.5
100 4 133 129 155 96 160 225 80 367 284 11.0 8.5
DN 50 100 : 2 4
ISO Projection Method EAll dims in mm
Fig. 26: Dimensions Stn. Stl. Flowmeter Primary DN 50:2 to DN 100:4, Wafer Design
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
20/48
20
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Dimensions Flowmeter Primary Variable Process Connections, Mod. DE21_ & DE23_
C
A
D
G1
F
EG
103
74
B12
73
83
199
120
5,5
MAG-XE COPA-XE MAG-XE COPA-XE
DN 3 40 : 1/10 1
DN Inch PN A D E F* G* G1*MAGXE
COPAXE(G)Weight appr. kg 1)
MAGXE(G1)Weight appr. kg1)
310 1/103/8 10 37 44 157 62 281 198 3.5 1.5
15 1/2 10 37 44 157 62 281 198 3.5 1.520 3/4 10 42 63 161 66 289 206 4 2
25 1 10 54 63 168 73 303 220 4.5 2.5
32 1 1/4 10 62 78 173 78 313 230 4.5 2.5
40 1 1/2 10 67 78 177 82 321 238 5 3
The above dimensions for COPAXE are for the design with an investment cast Alum. converter housing.Dimensions for stn. stl. converter housing see Page 23
* The dimensions G, G1 and F increase by 10.5 mm when a mounting bracket is usedInstallation lengths with the variable process connections see Page 221) Plus proceess connection adapter weight see Page 22
Mounting Bracket(option)
ISO Projection Method EAll dims in mm
Fig. 27: Dimensions Flowmeter Primary DN 3:1/10 to DN 40:1, Variable Process Connections
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
21/48
21
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Dimensions Flowmeter Primary Variable Process Connections, Mod. DE21_ & DE23_
73
E
G
F
60
A
D
G1
5,5
103 83
199
120
110
MAG-XE COPA-XE MAG-XE COPA-XE
DN 50 100 : 2 4
The above dimensions for COPAXE are for the design with an investment cast Alum. converter housing.Dimensions for stn. stl. converter housing see Page 23
* The dimensions G, G1 and F increase by 10.5 mm when a mounting bracket is usedInstallation lengths with the variable process connections see Page 221) Plus process connection adapter weight see Page 22
Mounting Bracket(option)
DN Inch PN A D E F* G* G1*MAGXE
COPAXE (G)Weight appr. kg 1)
MAGXE (G1)Weight appr. kg1)
50 2 10 128 100 185 50 297 214 6.5 4
65 2 1/2 10 114 116 199 58 319 236 7 4.5
80 3 10 114 133 205 67 334 251 9 6.5
100 4 10 144 160 225 80 367 284 11 8.5
DN 50 : 2 DN 65 100 : 2 4
ISO Projection Method EAll dims in mm
Fig. 28: Dimensions Flowmeter Primary DN 50:2 to DN 100:4, Variable Process Connections
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
22/48
22
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Dimensions Stainless Steel Flowmeter, Adapters for Variable Process Connections,Mod. DE21_ & DE23_
Weld stubs per DIN 11850 or
ISO 2037 or DIN 2463
Food Ind. Fittings per
DIN 11851
TriClamp per
DIN 32676
L
Di
Da
RdThd.
L L
Di
External threads
L
R
a
Meter Size
DN Inch
Weld Stubs
ISO 2037 DIN 11850 DIN 2463
Di Da L Wgt./kg Di Da L Wgt./kg Di Da L Wgt./kg
310 1/103/8 10.0 13.0 127 0.4 10.3 13.5 127 0.4 15 1/2 16.0 19.0 127 0.4 18.1 21.3 127 0.4
20 3/4 20.0 23.0 132 0.7 23.7 26.9 132 0.7
25 1 22.6 25.0 149 0.7 26.0 29.0 149 0.7 25 28 149 0.7
32 11/4 31.3 33.7 166 1.0 32.0 34.0 166 1.0 32 35 166 1.0
40 11/2 35.6 38.0 171 1.0 38.0 41.0 171 1.0 36.8 40 171 1.0
50 2 48.6 51.0 173 1.0 50.0 54.0 173 1.0 49 52 173 1.0
65 21/2 60.3 63.5 165 1.4 66.0 70.0 165 1.4 66 70 165 1.4
80 3 72.9 76.1 169 2.0 81.0 85.0 169 2.0 81 85 169 2.0
100 4 97.6 101.6 199 2.6 100.0 104.0 199 2.6 100 104 227 3.0
Meter Size
DN Inch
Food Ind. Fittings Tri-Clamp
DIN 11851 DIN 32676
Rd. Wgt. L Wgt./kg Di L Wgt./kg
310 1/103/8 28 x 1/8 169 0.5 10.0 163 0.5
15 1/2 34 x 1/8 169 0.5 16.0 163 0.5
20 3/4 44 x 1/6 180 0.9 20.0 168 0.7
25 1 52 x 1/6 207 0.9 26.0 192 0.8
32 11/4 58 x 1/6 230 1.4 32.0 209 1.5
40 11/2 65 x 1/6 237 1.4 38.0 214 1.4
50 2 78 x 1/6 243 1.4 50.0 216 1.2
65 21/2 95 x 1/6 245 2.2 66.0 221 1.6
80 3 110 x 1/4 259 3.2 81.0 225 2.4
100 4 130 x 1/4 307 4.4 100.0 255 3.1
External Threads ISO 228 / DIN 2999
Meter SizeDN Inch
R a L Weightkg1)
3 10 1/103/8 3/8 18 139 0.4
15 1/2 1/2 18 139 0.4
20 3/4 3/4 25 164 0.8
25 1 1 25 179 0.8
ISO Projection Method EAll dims in mm
Fig. 29: Dimensions Stn. Stl. Flowmeters DN 3:1/10 to DN 100:4, Adapters for Variable Process Connections
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
23/48
23
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Dimensions Converter Complete, Made of Stainless Steel for Mod. DE23_
Wafer Design Accessories for Model DE41W, DE43W,
DE21W, DE23WThe following accessories are available as a function of the meter sizeand the pressure rating:Bolts, nuts, lock washers, centering elementsGaskets are not included in the accessories.
Material: SS
Cable connector M20 x 1.5
73182.5
113.5
99
ISO Projection Method EAll dims in mm
Fig. 30: Dimensions Stn. Stl. Design COPAXE Model DE23_
Meter Size Pressure Rating Part Number
DN 3 to 101/10 to 3/8
PN 10 40 D614L265U03CL 150 D614L265U03
CL 300 D614L265U04
DN 151/2
PN 10 40 D614L265U03CL 150 D614L266U05CL 300 D614L266U06
DN 203/4
PN 10 40 D614L267U04CL 150 D614L267U05CL 300 D614L267U06
DN 251
PN 10 40 D614L268U04CL 150 D614L268U05
CL 300 D614L268U06DN 3211/4
PN 10 40 D614L269U04CL 150 D614L269U05
CL 300 D614L269U06DN 4011/2
PN 10 40 D614L270U04
CL 150 D614L270U05CL 300 D614L270U06DN 502
PN 10 40 D614L296U04CL 150 D614L296U05
CL 300 D614L296U06DN 6521/2
PN 10 16 D614L297U08CL 150 D614L297U10
DN 803
PN 10 40 D614L298U08CL 150 D614L298U09
DN 1004
PN 10 16 D614L299U07CL 150 D614L299U09
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
24/48
24
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Ordering Information Flanged Flowmeters, Mod. DE43F and DE41F
In addition to the Ordering Number please provide the following information: Fluid, fluid temperature, operating pressure, flow range, pipeline type,(ground plate, ground electrodes)
COPA-XE MAG-XEOrdering Number DE43F DE41FLinerHard rubberDN 15 10001/2 40
Soft rubberDN 50 10002 40PTFE DN 10 6003/8 24PFA DN 3 1001/10 4
H
STP
H
STP
Meter SizeDN 3 1/10DN 4 5/32DN 6 1/4DN 8 5/16
03040608
03040608
DN 10 3/8DN 15 1/2DN 20 3/4DN 25 1DN 32 11/4
1015202532
1015202532
DN 40 11/2DN 50 2DN 65 21/2DN 80 3
40506580
40506580
DN 100 4DN 125 5DN 150 6DN 200 8DN 250 10
1H1Q1F2H2F
1H1Q1F2H2F
DN 300 12DN 350 14DN 400 16DN 450 18DN 500 20DN 600 24
3H3F4H4F5H6H
3H3F4H4F5H6H
DN 700 28DN 800 32DN 900 36DN 1000 40
7H8H9H1T
7H8H9H1T
Signal/Ground Electrode Material 1)
SS (1.4571[316TI])/ none (std. for hard/soft rubber)Hastelloy B2 (2.4617)/ noneHastelloy C4 (2.4610)/ none (standard tor PTFE/PFA)
SBH
SBH
Titanium/ noneTantalum/ noneSS (1.4539)/ none
MTF
MTF
PlatinumIridium/ noneSS (1.4571)/ withHastelloy B2 (2.4617)/ withHastelloy C4 (2.4610)/ with
PENO
PENO
Titanium/ withTantalum/ withSS (1.4539)/ withPlatinumIridium/ with
IQRG
IQRG
Pressure RatingPN 10PN 16PN 25PN 40
CDEF
CDEF
JIS K10 (only up to DN 100:4)ANSI CL 150old installation length (only for replacements)ANSI CL 300old installation length (only for replacements)ANSI CL 150ISO installation lengthANSI CL 300 ISO installation length
KPQRS
KPQRS
Process ConnectionMaterial
Steel (standard from DN 20:3/4)1.4571[316Ti] Std.DN315:1/101/2
13
13
1)Ground electrodes available in meter sizes DN 3 300:1/10 12A conductive ground element in integrated in the hard/soft rubber liners in meter sizes DN 125 1000:5 40 as standard.Ground electrodes not required.
Continued on next Page
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
25/48
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
26/48
26
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Ordering Information for Wafer Design Flowmeters, Mod. DE43W and DE41W
In addition to the Ordering Number please provide the following information: Fluid, fluid temperature, operating pressure, flow range, pipeline type,(ground plate, ground electrodes)
COPA-XE MAG-XE
Ordering Number DE43W DE41W
LinerPTFEPFA
TP
TP
Meter SizeDN 3 1/10DN 4 5/32DN 6 1/4DN 8 5/16
03040608
03040608
DN 10 3/8DN 15 1/2DN 25 1DN 32 11/4DN 40 11/2
1015253240
1015253240
DN 50 2DN 65 21/2DN 80 3DN 100 4
5065801H
5065801H
Signal/Ground Electrode Material 1)SS (1.4571[316Ti]) / noneHastelloy B2 (2.4617) / noneHastelloy C4 (2.4610) / none (standard)
SBH
SBH
Titanium / noneTantalum / noneSS (1.4539) / none
MTF
MTF
PlatinumIridium / noneSS (1.4571) / withHastelloy B2 (2.4617) / withHastelloy C4 (2.4610) / with
PENO
PENO
Titanium / withTantalum / withSS (1.4539) / withPlatinumIridium / with
IQRG
IQRG
Pressure Rating PN 16 D DANSI CL 150 P P
CertificatesStandard (none)Matl Certificate 3.1B per EN10204 & Press. Test per AD2000Pressure Test per AD2000Inspection Test Report per EN10204 3.1B
ADGF
ADGF
Calibration CertificatesNoneCertified for Cold/Waste Water (DN 25 1000:1 40)Certified for Liquids other than Water
ABC
ABC
Protection Class IP 67 (threads for cable connector seesection Application)
2 IP 67 (thds. for cable connector M20 x1.5) std. IP 68(thds. for cable connector PG 13.5)IP 67 (thds. for cable connector NPT 1/2) IP 67 (thds. for cable connector PF 1/2)
2345
Supply Power High voltage 85 253 V ACLow voltage 16.8 26.4 V AC/16.8 31.2V DC
GK
Display Magnet Stick operation and lighted display D
1) Ground electrodes available in flowmeter sizes DN 3 100 : 1/10 4
Continued on next Page
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
27/48
27
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Additional Ordering Information to be provided in writing.
Note:Wafer Design accessories (bolts, nuts, lock washers)see Page 23
COPA-XE MAG-XE
Ordering Number DE43W DE41W
In-/Output OptionsCurrent outp. +Pulse outp. active +Contact inp. +Contact outp.Current outp. +Pulse outp. active +Contact inp. +Contact outp. +HARTProtocolCurrent outp. +Pulse outp. passive +Contact inp. +Contact outp.Current outp. +Pulse outp. passive +Contact inp. +Contact outp. +HARTProtocolCurrent outp. +Pulse outp. passive +Contact outp. +RS485Pulse outp. passive +Contact outp. +PROFIBUS DPPROFIBUS PA 3.0FOUNDATION FieldbusPROFIBUS PA 3.0 (with M12 plug)
010203040506141516
ApplicationConverter housing with threads for cable connector M 20 x 1.5 (standard)Converter housing with threads for cable connector NPT 1/2Converter housing with threads for cable connector PF 1/2
023
Name PlateGermanEnglishFrench
Excitation FrequencyDN 3 1000:1/1040 /6 1/4 Hz (50 Hz line)DN 3 100:1/104 /12 1/2 Hz (50 Hz line)DN 3 1000:1/1040 /7 1/2 Hz (60 Hz line)
DN 3 100:1/104 /15 Hz (60 Hz line)
Electrode DesignStandardPointed head (from DN10:3/8, SS1.4539), for high grease content
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
28/48
28
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Ordering Information Stainless Steel Flanged Flowmeter Designs DN 3 - DN 100 : 1/10 - 4
In addition to the Ordering Number please provide the following information: Fluid, fluid temperature, operating pressure, flow range, pipeline type,(ground plate, ground electrodes)
COPA-XE MAG-XE
Compact COPA-XE DE23F DE21F
Liner MaterialPFA P P
Meter Sizes DN 3 1/10DN 4 5/32DN 6 1/4DN 8 5/16DN 10 3/8
0304060810
0304060810
DN 15 1/2DN 20 3/4DN 25 1DN 32 11/4
15202532
15202532
DN 40 11/2DN 50 2DN 65 21/2DN 80 3DN 100 4
405065801H
405065801H
Signal/Ground Electrode Material 1)
SS 1.4571[316Ti] /noneHastelloy B2 (2.4617) /noneHastelloy C4 (2.4610) /none
Titanium /noneTantalum /noneSS 1.4539 /none (Food Ind. application.)PlatinumIridium /none
SBHMTFP
SBHMTFP
SS 1.4571[316Ti] /withHastelloy B2 (2.4617) /withHastelloy C4 (2.4610) /with
Titanium /withTantalum /withSS 1.4539 /with (Food Ind. application.)PlatinumIridium /with
ENOIQRG
ENOIQRG
Pressure RatingPN 16 (only DN 100:4)
PN 40 (DN 3 80:1/10 3)JIS K10
D
FK
D
FK
ANSI CL 150 (ISO installation length)ANSI CL 300 (ISO installation length)
PQ
PQ
Process Connection MaterialSS 1.4571[316Ti] 3 3
AccessoriesNoneProtection plates 1.4571[316Ti] (both sides)Ground plate 1.4571[316Ti] (one side)
ABC
ABC
Temperature RangeStandard temperature < 130 C S S
Certificates:Standard (none)Material Certificate 3.1B per EN10204 & Press. Test per AD2000
Pressure Test per AD2000Inspection Test Report per EN10204 3.1B
AD
GF
AD
FF
Calibration CertificatesNoneCertified for Cold/Waste Water (DN 25 1000:1 40)Certified for Liquids other than Water
ABC
ABC
Protection ClassIP 67 (threads for cable connector see Section Application) 2
IP 67 (Thds. for cable conn. PG13.5)IP 68 (Thds. for cable conn. PG13.5)
23
1) Ground electrodes available in flowmeter sizes DN 3 100 : 1/10 4
Continued on next Page
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
29/48
29
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Additional Ordering Information to be provided in writing.
COPA-XE MAG-XE
Compact COPA-XE DE23F DE21F
Supply PowerHigh voltage 85 253V ACLow voltage 16.8 26.4V AC/16.8 31.2V DC
GK
Display
Magnet Stick operation and lighted display DIn-/Output OptionsCurrent outp. +Pulse outp. active +Contact inp. +Contact outp.Current outp. +Pulse outp. active +Contact inp. +Contact outp. +HARTProtocolCurrent outp. +Pulse outp. passive +Contact inp. +Contact outp.Current outp. +Pulse outp. passive +Contact inp. +Contact outp. +HARTProtocolCurrent outp. +Pulse outp. passive +Contact outp. +RS485Pulse outp. passive +Contact outp. +PROFIBUS DPPROFIBUS PA 3.0FOUNDATION FieldbusPROFIBUS PA 3.0 (with M12 plug)
010203040506141516
ApplicationConverter housing, Aluminum with threads for cable connector M20 x 1.5Converter housing, stn. stl. with threads for cable connector M20 x 1.5Converter housing, Aluminum with threads for cable connector NPT 1/2Converter housing, Aluminum with threads for cable connector PF 1/2
0123
Name PlateGermanEnglishFrench
Excitation FrequencyDN3100:1/104 / 12 1/2 Hz (50 Hz line)DN3100:1/104 / 15 Hz (60 Hz line)
Electrode DesignStandardPointed head (from DN 10:3/8,Material 1.4539), for high grease content
Gasket MaterialEPDM with FDA ApprovalSilicone with FDA Approval
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
30/48
30
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Ordering Information Stainless Steel Flowmeter DN 3 - DN 100 : 1/10 - 4
COPA-XE MAG-XE
Compact COPA-XE DE23 DE21
Process Connections:External threads ISO 228 (only DN325:1/11)
Weld stubs n. ISO 2037 (only DN25100:14)Weld stubs per DIN2463Weld stubs per DIN 11850Food Ind. fittings per DIN 11851
TriClamp per DIN 32676No adapter (for replacement orders)Wafer DesignOthers
E
PQRSTVWZ
E
PQRST
VWZ
Liner MaterialPFA P P
Meter Sizes DN 3 1/10DN 4 3/32DN 6 1/4DN 8 5/16
03040608
03040608
DN 10 3/8
DN 15 1/2DN 20 3/4
10
1520
10
1520
DN 25 1DN 32 11/4DN 40 11/2
253240
253240
DN 50 2DN 65 212DN 80 3DN 100 4
5065801H
5065801H
Signal / Ground Electrode Material 1)
SS 1.4571[316Ti]/noneHastelloy B2 (2.4617)/noneHastelloy C4 (2.4610)/none standard
SBH
SBH
Titanium/noneTantalum/none
SS 1.4539/none (Food Ind. application.)
MT
F
MT
F
PlatinumIridium/noneSS 1.4571[316Ti]/withHastelloy B2 (2.4617)/withHastelloy C4 (2.4610)/with standard
PENO
PENO
Titanium/withTantalum/withSS 1.4539/with (Food Ind. application.)
IQR
IQR
PlatinumIridium G G
Pressure RatingPN 10 Standard for TriClamp, external threads,
Food Ind. fittingsC C
PN 16 (Wafer Design DN 3 100:1/104)PN 40 (Wafer Design DN 3 50:1/102)
ANSI CL 150 (Wafer Design DN 3 100:1/104)ANSI CL 300 (Wafer Design DN 3 50:1/102)
DF
PQ
DF
PQ
1)Ground electrodes available in flowmeter sizes DN 3 100 : 1/10 4
Continued on next Page
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
31/48
31
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Additional Ordering Information to be provided in writing.
Note:
Wafer Design accessories (bolts, nuts, lock washers)see Page 23
COPA-XE MAG-XE
Compact COPA-XE DE23 DE21
Process Connection MaterialNone (only Wafer Design)SS 1.4404 [ 316L]Others
049
049
Accessories NoneMounting bracket
AC
AC
Temperature Range Standard temperature< 130 C S S
CertificatesStandard (none)Material Certificate 3.1B per EN10204 & Press. Test per AD2000Pressure Test per AD2000Inspection Test Report per EN10204 3.1B
ADGF
ADGF
Calibration CertificatesNoneCertified for Cold/Waste Water (DN 25 1000:1 40)Certified for Liquids other than Water
ABC
ABC
Protection ClassIP 67 (threads for cable connector see Section Application) 2 IP 67 (Thds. for cable conn. PG13.5)
IP 68 (Thds. for cable conn. PG13.5)
2
3Supply PowerHigh voltage 85 253 V ACLow voltage 16.8 26.4 V AC / 16.8 31.2 V DC
KG
DisplayMagnet Stick operation and lighted display D
In-/Output OptionsCurrent outp. +Pulse outp. active +Contact inp. +Contact outp.Current outp. +Pulse outp. active +Contact inp. +Contact outp. +HARTProtocolCurrent outp. +Pulse outp. passive +Contact inp. +Contact outp.Current outp. +Pulse outp. passive +Contact inp. +Contact outp. +HARTProtocolCurrent outp. +Pulse outp. passive +Contact outp. +RS485Pulse outp. passive +Contact outp. +PROFIBUS DPPROFIBUS PA 3.0FOUNDATION Fieldbus
PROFIBUS PA 3.0 (with M12 plug)
0102030405061415
16ApplicationConverter housing, Aluminum with threads for cable connector M20 x 1.5Converter housing, stn. stl. with threads for cable connector M20 x 1.5Converter housing, Aluminum with threads for cable connector NPT 1/2Converter housing, Aluminum with threads for cable connector PF 1/2
0123
Name PlateGermanEnglishFrench
Excitation FrequencyDN 3 100: 1/104 /12 1/2 Hz (50 Hz line)DN 3 100: 1/104 /15 Hz (60 Hz line)
Electrode DesignStandardPointed head (from DN 10:3/8,Material 1.4539),for high grease content
Gasket Materiala) EPDM with FDA Approvalb) Silicone with FDA Approval
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
32/48
32
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Specifications Converter for COPA-XE and MAG-XE
Flow RangeContinuously adjustable between 0.5 and 10 m/s
Accuracy0.5 % of rate
Reproducibility 0.15 % of rate
Minimum Conductivity5 S/cm(20 S/cm for demineralized water)
Response TimeFor a step change 099 % (corresponds to 5 ) 1 s
Supply PowerHigh voltage AC: 85253 VLow voltage AC: 16.826.4 VLow voltage DC: 16.8 31.2 V, ripple: < 5 %
Magnetic Field Supply6 1/4, 7 1/2 Hz 12 Hz, 15 Hz(50/60 Hz supply power line frequency )
Power14 VA for AC supply power (flowmeter primary incl. converter)6 W for DC supply power DC (flowmeter primary incl. converter)
Ambient Temperature20 to +60 C see Temperature Diagram Page 9
Electrical ConnectionsSpring loaded screwless terminals
Protection Class per EN 60529IP 67, IP 68 (only MAGXE flowmeter primaries)
Forward/Reverse Flow MeteringFlow direction is indicated by direction arrows in the display andsignalled over the optocoupler output (ext. contact output).
DisplayIncludes a lighted display. Data can be entered using the 3 keypadbuttons or, without opening the housing, by using the Magnet Stick.
2x16character full graphic LCDdot matrixdisplay. The internal flowis totalized separately for each flow direction in one of 16
different direct reading engineering units. The flowrate is displayed inpercent or in one of 45 different direct reading engineering units. Theconverter housing can be rotated by 90. The display can be installedin 3 positions assuring optimal readability. In multiplex operation, inaddition to the display selections for the 1st and 2nd line, the flowratecan be displayed in %, direct reading engineering units, or as a bargraph, the totalizer value for the forward or reverse directions, the
TAG No. or current output value i.
Converter Housing Design Options
For Model COPA XECompact Design with converter housing made of cast light metal,painted, paint coat 60 m thick, rear section RAL 7012 dark gray,front section (cover) RAL 9002 light gray
Option:
Converter housing made of stainless steelFor Model MAG-XE
a) Field mount housing made of cast light metal, paintedpaint coat 60 m thick, rear section RAL 7012 dark gray, frontsection (cover) RAL 9002 light gray
b) 19 Insertc) Panel mount housingd) Housing for rail mounting
Weight:COPAXE: see Dimensions sectionMAGXE: Field mount housing: 4.5 kg
19 Insert: 1.5 kgRail mount housing: 1.2 kgPanel mount housing 1.2 kg
Signal Cable (only for MAG-XE)
The maximum cable length between the flowmeter primary and theconverter is 50 m. Each flowmeter system is shipped with a 10 m longsignal cable. If a length longer than 10 m is required, it should beordered using Part No. D173D018U02.
Plugable EEPROM
3 Sensors forMagnet StickOperation
3 Operator Buttons
Fig. 31: Converter Keypad and Display
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
33/48
33
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Display
The instantaneous flowrate in % of the flow range setting or direct readingengineering units is displayed. The value of the integrated flowrate is displayed in the 2nd line (including units).
The flowrate can be displayed in percent or one of 45 different directreading engineering units. The flow totals can be displayed in one of 16different units including liters, gallons, cubic meters, tons (if a density hasbeen entered). In addition it is possible to configure user defined units.
The low flow cutoff can be set between 0 and 10 % of max. (applies tothe current and pulse outputs and the displayed values).
The pulse factor, which can be set between 0.001 and 1000, is a multiplier for the values displayed.
The pulse width can be set between 0.1 ms and 2000 ms and isautomatically checked.
There are a number of languages available for the display.
Automatic self monitoring with a display of the error diagnostics and asignal over the contact output. All detected errors are stored in the errorregister.
The individual subassemblies in the converter can be tested. All outputscan be simulated for startup and test purposes.
F 70.01 %
F 10230 m3
Unit Qmax
l/s
Unit Totalizer
m3
Damping
10.000 s
Low flow cutoff
1.000 %
Pulse
1.000 /m3
Pulse width
100.000 ms
LanguageEnglish
Error register
0 ... 3 ...
Function test
Iout
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
34/48
34
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Isolation In- / OutputsThe current output and the pulse output are isolated from the input circuitand from each other.
1.) Analog Output Signals
a) Current output (Terminals +/-)0/420 mA load 600 ; 0/210 mA, load 1200 ;05 mA load 2400 selectable. Terminals: +/
b) Scaled Pulse Output (Terminals V8, V9 or Ux, V8)Scaled pulse output max. 5 kHz, pulse factor which can be set between0.001 and 1000 is a multiplier for the value displayed (1 pulse/m3x 1000).
The pulse width can be set between 0.1 ms and 2000 ms.A change between an active or passive configuration can be made usingjumpers.
c) Contact OutputThe following functions can be assigned to the contact output in thesoftware:System monitor: Normally opened or closed contactEmpty pipe: Normally opened or closed contactForward/Reverse: Contact closes for forward flow directionMaxAlarm, MinAlarm: Normally opened or closed contactMAXMINAlarm: Normally opened or closed contact
Optocoupler, (Terminals P7, G2 or Ux, P7)16 V UCEH
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
35/48
35
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
2.) Digital Communication
There are 5 digital communication options available:
a) The HART-ProtocolThe digital communication utilizes an alternating voltage superimposedon the current output. The instrument can be configured directly usingthe 3 buttons on the converter keypad or using the configuration andoperator software SMART VISIONtogether with the associated HART
DTM for SMART VISION
. (See below for more detailed information orthe separate Data Link Description, Part No. D184B108U01). The flowmeter is registered with the HART Communication Foundation.
b) The ASCII-ProtocolThe digital communication utilizes the RS485 data link.For more detailed information see the separate Data Link DescriptionPart No. D184B025U06
c) The PROFIBUS DP ProtocolThe digital communication utilizes a PROFIBUS DP connection board.This instrument can be configured directly using the 3 buttons on the onthe converter keypad or using the configuration and operator softwareSMART VISION. For more detailed information see the separate DataLink Description PROFIBUS DP Part No. D184B093U10.
d) The PROFIBUS PA-ProtocolThe digital communication utilizes IEC 611582
This instrument can be configured directly using the 3 buttons on the onthe converter keypad or using the configuration and operator softwareSMART VISIONand the associated PROFIBUS PA DTM. For moredetailed information see the separate Data Link Description PROFIBUSPA Part No. D184B093U26.
e) The FOUNDATION Fieldbus FFThe digital communication utilizes IEC 611582This instrument can be configured directly using the 3 buttons on theon the converter keypad or using the services integrated in the system orusing the National Configurator. For more detailed information see theseparate Data Link Description Part No. D184B093U18.
a) HART-Protocol
Transmission ModeFSK Modulation on the current output 420 mA per Bell 202 Standard.
Max. signal amplitude:1.2 mAppCurrent output load: min. 250, max. < 600Cable: AWG 24 twistedMax. cable length: 1500 m
b) ASCII-ProtocolTransmission technology: RS485 data linkV pp= 5 V. Input impedance: 12 kOhm,Max. cable length: 1200 m.Baudrate: 12009600 Baud.Max. 32 instruments in parallel on a single bus. A shielded cable withindividually twisted pairs is recommended.
Terminals: A and B
c) Profibus DP ProtocolTransmission technology RS 485 data link
Transmission speed 9.6 to 1500 kbit/sProtocol per EN 50170IdentNo. 6666 HEXCyclic (Output variables, see separate data link description for COPA/MAGXE)
CableA shielded twisted cable is recommended.Max. cable length 1200 m (cable type A)Characteristic resistance 135165
Max. 32 Instruments on a single busBaudrate: 9.61500 kbit/sDistributed capacitance < 30 pF/m, loop resistance 110 /km
The max. tap line length is a function of the baudrate and the number ofinstruments.Send and receive signals on the same terminal.
>V 205 l/min>V 28340 m3
PLS or PC
Rb = 250 Ohm
4 20 mA
202Modem
HART
Fig. 32: Communication with HARTProtocol
Terminal Function Reference
+VDAB
GND
VPRxD/TxDNRxD/TxDPC DGND
Supply voltage +5VReceive/senddataNReceive/senddataPData reference potential M5V
Fig. 33: ASCII Communication using RS485 Data Link
B A +VD GND
+5 VB A B A
Converter1
Converter2 32
Converter
PROFIBUS DP
Fig. 34: Bus Connections
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
36/48
36
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
d) PROFIBUS PA Protocol
The PROFIBUS PA data link in the COPAXE and the MAGXE conformsto Profile 3.0 (Standard PROFIBUS, EN 50170, DIN 19245 [PRO91]). Thetransmission signal from the converter corresponds to IEC 611582.
The manufacturer specific PROFIBUS PA IdentNo. of the COPAXE andthe MAGXE is: 0691 hex.
The instrument can be operated with the PROFIBUS StandardIdentNo.9700 or 9740.
For more detailed information see the separate Data Link DescriptionPart No. D184B093U26.
The stored data is maintained during a power outage.
CableA shielded and twisted cable is recommended (Type A or B cables asdefined in IEC 611582 are preferred).
Additional detailed project layout information may be found in theBrochure "PROFIBUS Solutions from ABB" (No. 30/FB10). Accessoriessuch as splitters, connectors and cables are itemized in List Sheet 10/636.44. There is also additional information available on our home pagehttp:// www.abb.de/Feldbus and on the home page of the PROFIBUSInternational Organization http://www.profibus.com.
Notes for Voltage / Current ValuesThe turnon behavior corresponds to Draft DIN IEC 65C/155/CDV ofJune 1996. The average current draw of the COPAXE or the MAGXE is13 mA. During an fault condition the current is limited to max. 17 mA bythe FDEFunction (=Fault Disconnection Electronic) integrated in the instrument.
The upper limit of the current is electronically limited.The voltage on the bus must be within the range 932 V DC.
Bus TopologyTree and/or linear structureBus termination: Passive at both ends of the main bus cable(RCcomponent R = 100 , C = 1 F)
e) FOUNDATION Fieldbus
The FOUNDATION Fieldbus data link conforms to the Standards FF890/891 as well as FF902/90. The transmission signal from the convertercorresponds to IEC 611582. The instrument is registered with the Fieldbus FOUNDATION. Interoperability Test campaign no. IT 019500.
The registration is listed with the Fieldbus FOUNDATION under the Manufacturer ID: 0x000320 and the Device ID 0x0016.
Setting the Bus AddressThe bus address FF is automatically assigned, although it can also be setmanually for the system. The address recognition is made by a uniquecombination of the ManufacturerID, DeviceID and Instrument SeriesNo.
Notes for Voltage / Current ValuesThe turnon behavior corresponds to Draft DIN IEC 65C/155/CDV ofJune 1996. The average current draw of the COPAXE or the MAGXE is13 mA. During an fault condition the current is limited to max. 17 mA bythe FDEFunction (=Fault Disconnection Electronic) integrated in the instrument.
The upper limit of the current is electronically limited.The voltage on the bus must be within the range 932 V DC.
System ConnectionConnection into a process control system requires a DDFile (Device Description file), which contains the description of the device and a CFFfile(Common File Format). The CFFfile is required to engineer the segment.
The engineering can be accomplished on or offline. Both files and theData Link Description are contained on a CD (Part No.: D699D002U01)included with the shipment. If required, it can be ordered from ABB at anytime at no cost. The files required for operation can also be downloadedfrom the website http://www. fieldbus.org.
Bus TopologyTree and/or linear structurePassive at both ends of the main bus cable(RCcomponent R = 100 , C = 1 F)
1 F
100
PROFIBUS DP PROFIBUS PA
H2Bus
PA+ PA PA+ PA PA+ PA
Segment Coupler
(incl. Bus supply
and termination)
Fig. 35: PROFIBUS PA Connection Example
Ethernet FOUNDATION Fieldbus H1
HSEBus
FF+ FF FF+ FF FF+ FF
Linking Device
(incl. Bus supply
and termination) 1 F
100
Fig. 36: FOUNDATION Fieldbus Connection Example
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
37/48
37
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Interconnection Diagram COPA-XE, Connection Options for Analog Communication (incl. HART)
10
C9
V9 V8 P7 G2 X1 +
9
2L
N
1L+
L
PE1)
b)
a)
2) 3) 4) 5)
E9 *)
Earth
1) a) Scaled Pulse Output, passive, Pulse width adjustable between 0.1 ms and 2000 ms,Terminals: V8, V9, Function E9, C9Optocoupler specifications:fmax5 kHz0 V UCEL2 V, 16 V UCEH30 V0 mA ICEH0.2 mA, 2 mA ICEL220 mA
b) Scaled Pulse Output, active Pulse width adjustable between 0.1 and 2000 ms, Terminals V8, V9, Function 9, 1020 mA < I 150 mA; fmax4 Hz, pulse width 50 ms, pulse T16V25 ms, 16 V U 30 V; on/off ratio 1:4 (Ton: Toff),fmax5 kHz, 2 mA I 20 mA; 16 V U 30 V
2) Contact Output, Function assigned in the software as System Monitor, Empty Pipe,Max.Min.Alarm or F/R signal*, Terminals G2, P7Optocoupler specifications:0 V UCEL2 V, 16 V UCEH30 V;0 mA ICEH0.2 mA, 2 mA ICEL220 mA
3) Contact Input, Function assigned in the software as external Zero Return, external Totalizer Reset, external Totalizer StopTerminals: G2, X1Optocoupler,16 V U 30 V, Ri = 2k
4) Current Output selectable, Terminals: +/, load 600 for 0/4 to 20 mA, load 1200 for 0/2 to 10 mA,load 2400 for 0 to 5 mA,Option: HARTProtocol
5) Supply Power, see Name Plate
*) The default factory setting is the Forward Direction signal.
Fig. 37: Interconnection Diagram COPAXE, Connection Options for Analog Communication (incl. HART)
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
38/48
38
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Interconnection Diagram COPA-XE, Connection Options for Digital Communication
(PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, ASCII)
Ux
Ux
a)
b)
c)
d)
V8
V8
P7
P7
+VD
FF+
PA+
A
PA
B
A
FF
+
B
GND N L
PE
1L+2L
Design a)
Terminals PA+, PA-Connections for PROFIBUS PA per IEC 611582 (Profile 3.0), (see Page 36)U = 932 V, I = 13 mA (normal operation); 17 mA (fault condition / FDE)
Design b)
Terminals Ux, V8Scaled Pulse Output, passive (Optocoupler), Pulse width adjustable between 0.1 ms to 2000 ms,Optocoupler specifications:fmax5 kHz0 V UCEL2 V, 16 V UCEH30 V;0 mA ICEH0.2 mA, 2 mA ICEL220 mA
Terminals Ux, P7Contact Output, Function assigned in the software as System Monitor, Empty Pipe,Max.Min.Alarm or F/R signalOptocoupler specifications:0 V UCEL2 V, 16 V UCEH30 V;0 mA ICEH0.2 mA, 2 mA ICEL220 mA
Terminals A, BSerial Data Link RS485 for communication using ASCIIProtocol
Terminals +, -Current Output, Terminals: +/, load 600 for 0/4 to 20 mA
Design c)Same as Design b), except
Terminals +VD, A, B, GNDConnections for PROFIBUS DP per EN 50170 (see Page 35)
Design d)
Terminals FF+, FF-Connections for FOUNDATION Fieldbus (H1) per IEC 611582U = 932 V, I = 13 mA (normal operation); 17 mA (fault condition / FDE)
Supply PowerSee Name Plate
a) PROFIBUS PA (Profile 3.0)b) RS485 (ASCII Protocol)c) PROFIBUS DPd) FOUNDATION Fieldbus
*)
Earth
Fig. 38: Interconnection Diagram COPAXE, Connection Options for Digital Communication
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
39/48
39
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Interconnection Diagram MAG-XE, Connection Options for Analog Communication (incl. HART)
10
C9 E9
V9 V8
M1
Earth Flowmeter Primary
Converter
Earth
M2 2 1 3 SE
P7 G2 X1 +
9
2L
N
PE
1) 2) 3) 4) 5)
1L+
L M1 M2 22S 1S1 3
Earth
Earth
Flowmeter Primary
Converter
L < 50 m
1) a) Scaled Pulse Output, passive, Pulse width adjustable between 0.1 ms to 2000 ms,Terminals: V8, V9, Function E9, C9,Optocoupler specifications: fmax5 kHz0 V UCEL 2 V, 16 V UCEH 30 V0 mA ICEH 0.2 mA, 2 mA ICEL 220 mA
b) Scaled Pulse Output, active Pulse width adjustable between 0.1 to 2000 ms, Terminals V8, V9, Function 9, 1020 mA < I 150 mA; fmax 4 Hz, Pulse width 50 ms, pulse T16V25 ms, 16 V U 30 Von/off ratio 1:4 (Ton: Toff), fmax5 kHz, 2 mA I 20 mA; 16 VU 30 V
2) Contact Output, Function assigned in the software as System Monitor, Empty Pipe,Max.Min.Alarm or F/R signal*, Terminals G2, P7Optocoupler specifications:0 VUCEL2 V, 16 V UCEH30 V;0 mA ICEH0.2 mA, 2 mA ICEL220 mA
3) Contact Input, Function assigned in the software as external Zero Return, external Totalizer Reset, external Totalizer StopTerminals: G2, X1
Optocoupler, 16 VU 30 V, Ri = 2k4) Current Output selectable, Terminals: +/, load 600 for 0/4 to 20 mA, load 1200 for 0/2 to 10 mA,load 2400 for 0 to 5 mAOption: HARTProtocol
5) Supply Power, see Name Plate
*) The default factory setting is Forward Direction signal.
Fig. 39: Interconnection Diagram MAGXE, Connection Options for Analog Communication (incl. HART)
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
40/48
40
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Interconnection Diagram MAG-XE, Connection Options for Digital Communication (PROFIBUS DP,PROFIBUS PA, FOUNDATION Fieldbus, ASCII)
M1
Earth Flowmeter Primary
Converter
Earth
M2 2 1 3 SE
PE
M1 M2 22S 1S1 3Ux
Uxa)b)
c)
d)
V8
V8
P7
P7
+VD
FF+
PA+A
PAB
A
FF
+
B
GND N L
1L+2L
a) PROFIBUS PA (Profile 3.0)b) RS485 (ASCII Protocol)c) PROFIBUS DPd) FOUNDATION Fieldbus
Design a)
Terminals PA+, PA-Connections for PROFIBUS PA per IEC 611582 (Profile 3.0), (see Page 36)U = 932 V, I = 13 mA (normal operation); 17 mA (fault condition / FDE)
Design b)
Terminals Ux, V8Scaled Pulse Output, passive (optocoupler),Pulse width adjustable between 0.1 ms to 2000 ms,Optocoupler specifications:fmax5 kHz0 V UCEL2 V, 16 V UCEH30 V;0 mA ICEH0.2 mA, 2 mA ICEL220 mA
Terminals Ux, P7Contact Output, Function assigned in the softwareas System Monitor, Empty Pipe,Max.Min.Alarm or F/R signalOptocoupler specifications:0 V UCEL2 V, 16 V UCEH30 V;0 mA ICEH0.2 mA, 2 mA ICEL220 mA
Terminals A, BSerial Data Link RS485 for Communication using ASCIIProtocol
Terminals +, -Current Output, Terminals: +/, load600 for 0/4 to 20 mA
Design c)Same as Design b), except
Terminals +VD, A, B, GNDConnections for PROFIBUS DP per EN 50170(see Page 35)
Design d)Terminals FF+, FF-Connections for FOUNDATION Fieldbus (H1) per IEC 611582U = 932 V, I = 13 mA (normal operation); 17 mA (fault condition
/ FDE)
Supply PowerSee Name Plate
Earth
Earth
Flowmeter Primary
Converter
L < 50 m
Fig. 40: Interconnection Diagram MAGXE, Connection Options for Digital Communication (PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, ASCII)
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
41/48
41
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Interconnection Examples for Peripherals with Analog Communication (incl. HART)
+
externalinternal
Current Output
0/420 mA
0/210 mA05 mA010, 1020 mA412, 1220 mA
0/420 mA load: max. 600 Ohm0/210 mA load: max. 1200 Ohm0 5 mA load: max. 2400 Ohm
* RBU
CE
ICE
-------------
V8
(E9)
24 V+
externalinternal
Pulse Output (Optocoupler)
RB*V9(C9)
Imax= 220 mA
V9(10)
V8
(9)
24 V+
externalinternalPulse Output active
X1
G2
externalinternal
+24 V
Contact Input for External Zero Return
Function assigned in software
0 V
Contact setting:Output is turned off whencontact is closed.
Ri= 2k
X1
G2
externalinternal
+24 V
External Totalizer Reset
0 V
Contact setting:internal totalizer to zero,when contact is closed.
Ri= 2k
or
P7
G2
externalinternal
Contact Output for System Monitor, Max.-Min.-Alarm,
Empty Pipe or Forward/Reverse Direction Signal
RB*+U
Function assigned in software
Imax= 220 mA
G2
P7
externalinternal
V9(C9)
V8(E9)
24 V+
Pulse Output passive Optocoupler,
Separate Forward and Reverse Pulses
on Contact Output
Fig. 41: Interconnection Examples for Peripherals with Analog Communication (incl. HART)
8/11/2019 ABB_FXE4000 - Medidor Eletromagnetico
42/48
42
Electromagnetic Flowmeter FXE4000 D184S044U02(COPAXE/MAGXE)
Interconnection Examples for Peripherals with Digital Communication (PROFIBUS DP,PROFIBUS PA, FOUND